linux/arch/s390/kernel/signal.c

481 lines
14 KiB
C
Raw Normal View History

/*
* Copyright IBM Corp. 1999, 2006
* Author(s): Denis Joseph Barrow (djbarrow@de.ibm.com,barrow_dj@yahoo.com)
*
* Based on Intel version
*
* Copyright (C) 1991, 1992 Linus Torvalds
*
* 1997-11-28 Modified for POSIX.1b signals by Richard Henderson
*/
#include <linux/sched.h>
#include <linux/mm.h>
#include <linux/smp.h>
#include <linux/kernel.h>
#include <linux/signal.h>
#include <linux/errno.h>
#include <linux/wait.h>
#include <linux/ptrace.h>
#include <linux/unistd.h>
#include <linux/stddef.h>
#include <linux/tty.h>
#include <linux/personality.h>
#include <linux/binfmts.h>
#include <linux/tracehook.h>
#include <linux/syscalls.h>
#include <linux/compat.h>
#include <asm/ucontext.h>
#include <asm/uaccess.h>
#include <asm/lowcore.h>
#include <asm/switch_to.h>
#include "entry.h"
typedef struct
{
__u8 callee_used_stack[__SIGNAL_FRAMESIZE];
struct sigcontext sc;
_sigregs sregs;
int signo;
__u8 retcode[S390_SYSCALL_SIZE];
} sigframe;
typedef struct
{
__u8 callee_used_stack[__SIGNAL_FRAMESIZE];
__u8 retcode[S390_SYSCALL_SIZE];
struct siginfo info;
struct ucontext uc;
} rt_sigframe;
/*
* Atomically swap in the new signal mask, and wait for a signal.
*/
SYSCALL_DEFINE3(sigsuspend, int, history0, int, history1, old_sigset_t, mask)
{
sigset_t blocked;
siginitset(&blocked, mask);
return sigsuspend(&blocked);
}
SYSCALL_DEFINE3(sigaction, int, sig, const struct old_sigaction __user *, act,
struct old_sigaction __user *, oact)
{
struct k_sigaction new_ka, old_ka;
int ret;
if (act) {
old_sigset_t mask;
if (!access_ok(VERIFY_READ, act, sizeof(*act)) ||
__get_user(new_ka.sa.sa_handler, &act->sa_handler) ||
__get_user(new_ka.sa.sa_restorer, &act->sa_restorer) ||
__get_user(new_ka.sa.sa_flags, &act->sa_flags) ||
__get_user(mask, &act->sa_mask))
return -EFAULT;
siginitset(&new_ka.sa.sa_mask, mask);
}
ret = do_sigaction(sig, act ? &new_ka : NULL, oact ? &old_ka : NULL);
if (!ret && oact) {
if (!access_ok(VERIFY_WRITE, oact, sizeof(*oact)) ||
__put_user(old_ka.sa.sa_handler, &oact->sa_handler) ||
__put_user(old_ka.sa.sa_restorer, &oact->sa_restorer) ||
__put_user(old_ka.sa.sa_flags, &oact->sa_flags) ||
__put_user(old_ka.sa.sa_mask.sig[0], &oact->sa_mask))
return -EFAULT;
}
return ret;
}
SYSCALL_DEFINE2(sigaltstack, const stack_t __user *, uss,
stack_t __user *, uoss)
{
struct pt_regs *regs = task_pt_regs(current);
return do_sigaltstack(uss, uoss, regs->gprs[15]);
}
/* Returns non-zero on fault. */
static int save_sigregs(struct pt_regs *regs, _sigregs __user *sregs)
{
_sigregs user_sregs;
save_access_regs(current->thread.acrs);
/* Copy a 'clean' PSW mask to the user to avoid leaking
information about whether PER is currently on. */
user_sregs.regs.psw.mask = psw_user_bits |
(regs->psw.mask & PSW_MASK_USER);
user_sregs.regs.psw.addr = regs->psw.addr;
memcpy(&user_sregs.regs.gprs, &regs->gprs, sizeof(sregs->regs.gprs));
memcpy(&user_sregs.regs.acrs, current->thread.acrs,
sizeof(sregs->regs.acrs));
/*
* We have to store the fp registers to current->thread.fp_regs
* to merge them with the emulated registers.
*/
save_fp_regs(&current->thread.fp_regs);
memcpy(&user_sregs.fpregs, &current->thread.fp_regs,
sizeof(s390_fp_regs));
return __copy_to_user(sregs, &user_sregs, sizeof(_sigregs));
}
/* Returns positive number on error */
static int restore_sigregs(struct pt_regs *regs, _sigregs __user *sregs)
{
int err;
_sigregs user_sregs;
/* Alwys make any pending restarted system call return -EINTR */
current_thread_info()->restart_block.fn = do_no_restart_syscall;
err = __copy_from_user(&user_sregs, sregs, sizeof(_sigregs));
if (err)
return err;
/* Use regs->psw.mask instead of psw_user_bits to preserve PER bit. */
regs->psw.mask = (regs->psw.mask & ~PSW_MASK_USER) |
(user_sregs.regs.psw.mask & PSW_MASK_USER);
/* Check for invalid user address space control. */
if ((regs->psw.mask & PSW_MASK_ASC) >= (psw_kernel_bits & PSW_MASK_ASC))
regs->psw.mask = (psw_user_bits & PSW_MASK_ASC) |
(regs->psw.mask & ~PSW_MASK_ASC);
/* Check for invalid amode */
if (regs->psw.mask & PSW_MASK_EA)
regs->psw.mask |= PSW_MASK_BA;
regs->psw.addr = user_sregs.regs.psw.addr;
memcpy(&regs->gprs, &user_sregs.regs.gprs, sizeof(sregs->regs.gprs));
memcpy(&current->thread.acrs, &user_sregs.regs.acrs,
sizeof(sregs->regs.acrs));
restore_access_regs(current->thread.acrs);
memcpy(&current->thread.fp_regs, &user_sregs.fpregs,
sizeof(s390_fp_regs));
current->thread.fp_regs.fpc &= FPC_VALID_MASK;
restore_fp_regs(&current->thread.fp_regs);
clear_thread_flag(TIF_SYSCALL); /* No longer in a system call */
return 0;
}
SYSCALL_DEFINE0(sigreturn)
{
struct pt_regs *regs = task_pt_regs(current);
sigframe __user *frame = (sigframe __user *)regs->gprs[15];
sigset_t set;
if (!access_ok(VERIFY_READ, frame, sizeof(*frame)))
goto badframe;
if (__copy_from_user(&set.sig, &frame->sc.oldmask, _SIGMASK_COPY_SIZE))
goto badframe;
set_current_blocked(&set);
if (restore_sigregs(regs, &frame->sregs))
goto badframe;
return regs->gprs[2];
badframe:
force_sig(SIGSEGV, current);
return 0;
}
SYSCALL_DEFINE0(rt_sigreturn)
{
struct pt_regs *regs = task_pt_regs(current);
rt_sigframe __user *frame = (rt_sigframe __user *)regs->gprs[15];
sigset_t set;
if (!access_ok(VERIFY_READ, frame, sizeof(*frame)))
goto badframe;
if (__copy_from_user(&set.sig, &frame->uc.uc_sigmask, sizeof(set)))
goto badframe;
set_current_blocked(&set);
if (restore_sigregs(regs, &frame->uc.uc_mcontext))
goto badframe;
if (do_sigaltstack(&frame->uc.uc_stack, NULL,
regs->gprs[15]) == -EFAULT)
goto badframe;
return regs->gprs[2];
badframe:
force_sig(SIGSEGV, current);
return 0;
}
/*
* Set up a signal frame.
*/
/*
* Determine which stack to use..
*/
static inline void __user *
get_sigframe(struct k_sigaction *ka, struct pt_regs * regs, size_t frame_size)
{
unsigned long sp;
/* Default to using normal stack */
sp = regs->gprs[15];
/* Overflow on alternate signal stack gives SIGSEGV. */
if (on_sig_stack(sp) && !on_sig_stack((sp - frame_size) & -8UL))
return (void __user *) -1UL;
/* This is the X/Open sanctioned signal stack switching. */
if (ka->sa.sa_flags & SA_ONSTACK) {
if (! sas_ss_flags(sp))
sp = current->sas_ss_sp + current->sas_ss_size;
}
return (void __user *)((sp - frame_size) & -8ul);
}
static inline int map_signal(int sig)
{
if (current_thread_info()->exec_domain
&& current_thread_info()->exec_domain->signal_invmap
&& sig < 32)
return current_thread_info()->exec_domain->signal_invmap[sig];
else
return sig;
}
static int setup_frame(int sig, struct k_sigaction *ka,
sigset_t *set, struct pt_regs * regs)
{
sigframe __user *frame;
frame = get_sigframe(ka, regs, sizeof(sigframe));
if (!access_ok(VERIFY_WRITE, frame, sizeof(sigframe)))
goto give_sigsegv;
if (frame == (void __user *) -1UL)
goto give_sigsegv;
if (__copy_to_user(&frame->sc.oldmask, &set->sig, _SIGMASK_COPY_SIZE))
goto give_sigsegv;
if (save_sigregs(regs, &frame->sregs))
goto give_sigsegv;
if (__put_user(&frame->sregs, &frame->sc.sregs))
goto give_sigsegv;
/* Set up to return from userspace. If provided, use a stub
already in userspace. */
if (ka->sa.sa_flags & SA_RESTORER) {
regs->gprs[14] = (unsigned long)
ka->sa.sa_restorer | PSW_ADDR_AMODE;
} else {
regs->gprs[14] = (unsigned long)
frame->retcode | PSW_ADDR_AMODE;
if (__put_user(S390_SYSCALL_OPCODE | __NR_sigreturn,
(u16 __user *)(frame->retcode)))
goto give_sigsegv;
}
/* Set up backchain. */
if (__put_user(regs->gprs[15], (addr_t __user *) frame))
goto give_sigsegv;
/* Set up registers for signal handler */
regs->gprs[15] = (unsigned long) frame;
/* Force default amode and default user address space control. */
regs->psw.mask = PSW_MASK_EA | PSW_MASK_BA |
(psw_user_bits & PSW_MASK_ASC) |
(regs->psw.mask & ~PSW_MASK_ASC);
regs->psw.addr = (unsigned long) ka->sa.sa_handler | PSW_ADDR_AMODE;
regs->gprs[2] = map_signal(sig);
regs->gprs[3] = (unsigned long) &frame->sc;
/* We forgot to include these in the sigcontext.
To avoid breaking binary compatibility, they are passed as args. */
if (sig == SIGSEGV || sig == SIGBUS || sig == SIGILL ||
sig == SIGTRAP || sig == SIGFPE) {
/* set extra registers only for synchronous signals */
regs->gprs[4] = regs->int_code & 127;
regs->gprs[5] = regs->int_parm_long;
regs->gprs[6] = task_thread_info(current)->last_break;
}
/* Place signal number on stack to allow backtrace from handler. */
if (__put_user(regs->gprs[2], (int __user *) &frame->signo))
goto give_sigsegv;
return 0;
give_sigsegv:
force_sigsegv(sig, current);
return -EFAULT;
}
static int setup_rt_frame(int sig, struct k_sigaction *ka, siginfo_t *info,
sigset_t *set, struct pt_regs * regs)
{
int err = 0;
rt_sigframe __user *frame;
frame = get_sigframe(ka, regs, sizeof(rt_sigframe));
if (!access_ok(VERIFY_WRITE, frame, sizeof(rt_sigframe)))
goto give_sigsegv;
if (frame == (void __user *) -1UL)
goto give_sigsegv;
if (copy_siginfo_to_user(&frame->info, info))
goto give_sigsegv;
/* Create the ucontext. */
err |= __put_user(0, &frame->uc.uc_flags);
err |= __put_user(NULL, &frame->uc.uc_link);
err |= __put_user((void __user *)current->sas_ss_sp, &frame->uc.uc_stack.ss_sp);
err |= __put_user(sas_ss_flags(regs->gprs[15]),
&frame->uc.uc_stack.ss_flags);
err |= __put_user(current->sas_ss_size, &frame->uc.uc_stack.ss_size);
err |= save_sigregs(regs, &frame->uc.uc_mcontext);
err |= __copy_to_user(&frame->uc.uc_sigmask, set, sizeof(*set));
if (err)
goto give_sigsegv;
/* Set up to return from userspace. If provided, use a stub
already in userspace. */
if (ka->sa.sa_flags & SA_RESTORER) {
regs->gprs[14] = (unsigned long)
ka->sa.sa_restorer | PSW_ADDR_AMODE;
} else {
regs->gprs[14] = (unsigned long)
frame->retcode | PSW_ADDR_AMODE;
if (__put_user(S390_SYSCALL_OPCODE | __NR_rt_sigreturn,
(u16 __user *)(frame->retcode)))
goto give_sigsegv;
}
/* Set up backchain. */
if (__put_user(regs->gprs[15], (addr_t __user *) frame))
goto give_sigsegv;
/* Set up registers for signal handler */
regs->gprs[15] = (unsigned long) frame;
/* Force default amode and default user address space control. */
regs->psw.mask = PSW_MASK_EA | PSW_MASK_BA |
(psw_user_bits & PSW_MASK_ASC) |
(regs->psw.mask & ~PSW_MASK_ASC);
regs->psw.addr = (unsigned long) ka->sa.sa_handler | PSW_ADDR_AMODE;
regs->gprs[2] = map_signal(sig);
regs->gprs[3] = (unsigned long) &frame->info;
regs->gprs[4] = (unsigned long) &frame->uc;
regs->gprs[5] = task_thread_info(current)->last_break;
return 0;
give_sigsegv:
force_sigsegv(sig, current);
return -EFAULT;
}
static void handle_signal(unsigned long sig, struct k_sigaction *ka,
siginfo_t *info, sigset_t *oldset,
struct pt_regs *regs)
{
int ret;
/* Set up the stack frame */
if (ka->sa.sa_flags & SA_SIGINFO)
ret = setup_rt_frame(sig, ka, info, oldset, regs);
else
ret = setup_frame(sig, ka, oldset, regs);
if (ret)
return;
signal_delivered(sig, info, ka, regs,
test_thread_flag(TIF_SINGLE_STEP));
}
/*
* Note that 'init' is a special process: it doesn't get signals it doesn't
* want to handle. Thus you cannot kill init even with a SIGKILL even by
* mistake.
*
* Note that we go through the signals twice: once to check the signals that
* the kernel can handle, and then we build all the user-level signal handling
* stack-frames in one go after that.
*/
void do_signal(struct pt_regs *regs)
{
siginfo_t info;
int signr;
struct k_sigaction ka;
sigset_t *oldset = sigmask_to_save();
[S390] signal race with restarting system calls For a ERESTARTNOHAND/ERESTARTSYS/ERESTARTNOINTR restarting system call do_signal will prepare the restart of the system call with a rewind of the PSW before calling get_signal_to_deliver (where the debugger might take control). For A ERESTART_RESTARTBLOCK restarting system call do_signal will set -EINTR as return code. There are two issues with this approach: 1) strace never sees ERESTARTNOHAND, ERESTARTSYS, ERESTARTNOINTR or ERESTART_RESTARTBLOCK as the rewinding already took place or the return code has been changed to -EINTR 2) if get_signal_to_deliver does not return with a signal to deliver the restart via the repeat of the svc instruction is left in place. This opens a race if another signal is made pending before the system call instruction can be reexecuted. The original system call will be restarted even if the second signal would have ended the system call with -EINTR. These two issues can be solved by dropping the early rewind of the system call before get_signal_to_deliver has been called and by using the TIF_RESTART_SVC magic to do the restart if no signal has to be delivered. The only situation where the system call restart via the repeat of the svc instruction is appropriate is when a SA_RESTART signal is delivered to user space. Unfortunately this breaks inferior calls by the debugger again. The system call number and the length of the system call instruction is lost over the inferior call and user space will see ERESTARTNOHAND/ ERESTARTSYS/ERESTARTNOINTR/ERESTART_RESTARTBLOCK. To correct this a new ptrace interface is added to save/restore the system call number and system call instruction length. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2011-10-30 15:16:47 +01:00
/*
* Get signal to deliver. When running under ptrace, at this point
* the debugger may change all our registers, including the system
* call information.
*/
current_thread_info()->system_call =
test_thread_flag(TIF_SYSCALL) ? regs->int_code : 0;
signr = get_signal_to_deliver(&info, &ka, regs, NULL);
if (signr > 0) {
/* Whee! Actually deliver the signal. */
if (current_thread_info()->system_call) {
regs->int_code = current_thread_info()->system_call;
[S390] signal race with restarting system calls For a ERESTARTNOHAND/ERESTARTSYS/ERESTARTNOINTR restarting system call do_signal will prepare the restart of the system call with a rewind of the PSW before calling get_signal_to_deliver (where the debugger might take control). For A ERESTART_RESTARTBLOCK restarting system call do_signal will set -EINTR as return code. There are two issues with this approach: 1) strace never sees ERESTARTNOHAND, ERESTARTSYS, ERESTARTNOINTR or ERESTART_RESTARTBLOCK as the rewinding already took place or the return code has been changed to -EINTR 2) if get_signal_to_deliver does not return with a signal to deliver the restart via the repeat of the svc instruction is left in place. This opens a race if another signal is made pending before the system call instruction can be reexecuted. The original system call will be restarted even if the second signal would have ended the system call with -EINTR. These two issues can be solved by dropping the early rewind of the system call before get_signal_to_deliver has been called and by using the TIF_RESTART_SVC magic to do the restart if no signal has to be delivered. The only situation where the system call restart via the repeat of the svc instruction is appropriate is when a SA_RESTART signal is delivered to user space. Unfortunately this breaks inferior calls by the debugger again. The system call number and the length of the system call instruction is lost over the inferior call and user space will see ERESTARTNOHAND/ ERESTARTSYS/ERESTARTNOINTR/ERESTART_RESTARTBLOCK. To correct this a new ptrace interface is added to save/restore the system call number and system call instruction length. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2011-10-30 15:16:47 +01:00
/* Check for system call restarting. */
switch (regs->gprs[2]) {
case -ERESTART_RESTARTBLOCK:
case -ERESTARTNOHAND:
regs->gprs[2] = -EINTR;
break;
case -ERESTARTSYS:
if (!(ka.sa.sa_flags & SA_RESTART)) {
regs->gprs[2] = -EINTR;
break;
}
/* fallthrough */
case -ERESTARTNOINTR:
regs->gprs[2] = regs->orig_gpr2;
regs->psw.addr =
__rewind_psw(regs->psw,
regs->int_code >> 16);
[S390] signal race with restarting system calls For a ERESTARTNOHAND/ERESTARTSYS/ERESTARTNOINTR restarting system call do_signal will prepare the restart of the system call with a rewind of the PSW before calling get_signal_to_deliver (where the debugger might take control). For A ERESTART_RESTARTBLOCK restarting system call do_signal will set -EINTR as return code. There are two issues with this approach: 1) strace never sees ERESTARTNOHAND, ERESTARTSYS, ERESTARTNOINTR or ERESTART_RESTARTBLOCK as the rewinding already took place or the return code has been changed to -EINTR 2) if get_signal_to_deliver does not return with a signal to deliver the restart via the repeat of the svc instruction is left in place. This opens a race if another signal is made pending before the system call instruction can be reexecuted. The original system call will be restarted even if the second signal would have ended the system call with -EINTR. These two issues can be solved by dropping the early rewind of the system call before get_signal_to_deliver has been called and by using the TIF_RESTART_SVC magic to do the restart if no signal has to be delivered. The only situation where the system call restart via the repeat of the svc instruction is appropriate is when a SA_RESTART signal is delivered to user space. Unfortunately this breaks inferior calls by the debugger again. The system call number and the length of the system call instruction is lost over the inferior call and user space will see ERESTARTNOHAND/ ERESTARTSYS/ERESTARTNOINTR/ERESTART_RESTARTBLOCK. To correct this a new ptrace interface is added to save/restore the system call number and system call instruction length. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2011-10-30 15:16:47 +01:00
break;
}
}
/* No longer in a system call */
clear_thread_flag(TIF_SYSCALL);
[S390] signal race with restarting system calls For a ERESTARTNOHAND/ERESTARTSYS/ERESTARTNOINTR restarting system call do_signal will prepare the restart of the system call with a rewind of the PSW before calling get_signal_to_deliver (where the debugger might take control). For A ERESTART_RESTARTBLOCK restarting system call do_signal will set -EINTR as return code. There are two issues with this approach: 1) strace never sees ERESTARTNOHAND, ERESTARTSYS, ERESTARTNOINTR or ERESTART_RESTARTBLOCK as the rewinding already took place or the return code has been changed to -EINTR 2) if get_signal_to_deliver does not return with a signal to deliver the restart via the repeat of the svc instruction is left in place. This opens a race if another signal is made pending before the system call instruction can be reexecuted. The original system call will be restarted even if the second signal would have ended the system call with -EINTR. These two issues can be solved by dropping the early rewind of the system call before get_signal_to_deliver has been called and by using the TIF_RESTART_SVC magic to do the restart if no signal has to be delivered. The only situation where the system call restart via the repeat of the svc instruction is appropriate is when a SA_RESTART signal is delivered to user space. Unfortunately this breaks inferior calls by the debugger again. The system call number and the length of the system call instruction is lost over the inferior call and user space will see ERESTARTNOHAND/ ERESTARTSYS/ERESTARTNOINTR/ERESTART_RESTARTBLOCK. To correct this a new ptrace interface is added to save/restore the system call number and system call instruction length. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2011-10-30 15:16:47 +01:00
if (is_compat_task())
handle_signal32(signr, &ka, &info, oldset, regs);
else
handle_signal(signr, &ka, &info, oldset, regs);
return;
}
[S390] signal race with restarting system calls For a ERESTARTNOHAND/ERESTARTSYS/ERESTARTNOINTR restarting system call do_signal will prepare the restart of the system call with a rewind of the PSW before calling get_signal_to_deliver (where the debugger might take control). For A ERESTART_RESTARTBLOCK restarting system call do_signal will set -EINTR as return code. There are two issues with this approach: 1) strace never sees ERESTARTNOHAND, ERESTARTSYS, ERESTARTNOINTR or ERESTART_RESTARTBLOCK as the rewinding already took place or the return code has been changed to -EINTR 2) if get_signal_to_deliver does not return with a signal to deliver the restart via the repeat of the svc instruction is left in place. This opens a race if another signal is made pending before the system call instruction can be reexecuted. The original system call will be restarted even if the second signal would have ended the system call with -EINTR. These two issues can be solved by dropping the early rewind of the system call before get_signal_to_deliver has been called and by using the TIF_RESTART_SVC magic to do the restart if no signal has to be delivered. The only situation where the system call restart via the repeat of the svc instruction is appropriate is when a SA_RESTART signal is delivered to user space. Unfortunately this breaks inferior calls by the debugger again. The system call number and the length of the system call instruction is lost over the inferior call and user space will see ERESTARTNOHAND/ ERESTARTSYS/ERESTARTNOINTR/ERESTART_RESTARTBLOCK. To correct this a new ptrace interface is added to save/restore the system call number and system call instruction length. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2011-10-30 15:16:47 +01:00
/* No handlers present - check for system call restart */
clear_thread_flag(TIF_SYSCALL);
if (current_thread_info()->system_call) {
regs->int_code = current_thread_info()->system_call;
[S390] signal race with restarting system calls For a ERESTARTNOHAND/ERESTARTSYS/ERESTARTNOINTR restarting system call do_signal will prepare the restart of the system call with a rewind of the PSW before calling get_signal_to_deliver (where the debugger might take control). For A ERESTART_RESTARTBLOCK restarting system call do_signal will set -EINTR as return code. There are two issues with this approach: 1) strace never sees ERESTARTNOHAND, ERESTARTSYS, ERESTARTNOINTR or ERESTART_RESTARTBLOCK as the rewinding already took place or the return code has been changed to -EINTR 2) if get_signal_to_deliver does not return with a signal to deliver the restart via the repeat of the svc instruction is left in place. This opens a race if another signal is made pending before the system call instruction can be reexecuted. The original system call will be restarted even if the second signal would have ended the system call with -EINTR. These two issues can be solved by dropping the early rewind of the system call before get_signal_to_deliver has been called and by using the TIF_RESTART_SVC magic to do the restart if no signal has to be delivered. The only situation where the system call restart via the repeat of the svc instruction is appropriate is when a SA_RESTART signal is delivered to user space. Unfortunately this breaks inferior calls by the debugger again. The system call number and the length of the system call instruction is lost over the inferior call and user space will see ERESTARTNOHAND/ ERESTARTSYS/ERESTARTNOINTR/ERESTART_RESTARTBLOCK. To correct this a new ptrace interface is added to save/restore the system call number and system call instruction length. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2011-10-30 15:16:47 +01:00
switch (regs->gprs[2]) {
case -ERESTART_RESTARTBLOCK:
/* Restart with sys_restart_syscall */
regs->int_code = __NR_restart_syscall;
[S390] signal race with restarting system calls For a ERESTARTNOHAND/ERESTARTSYS/ERESTARTNOINTR restarting system call do_signal will prepare the restart of the system call with a rewind of the PSW before calling get_signal_to_deliver (where the debugger might take control). For A ERESTART_RESTARTBLOCK restarting system call do_signal will set -EINTR as return code. There are two issues with this approach: 1) strace never sees ERESTARTNOHAND, ERESTARTSYS, ERESTARTNOINTR or ERESTART_RESTARTBLOCK as the rewinding already took place or the return code has been changed to -EINTR 2) if get_signal_to_deliver does not return with a signal to deliver the restart via the repeat of the svc instruction is left in place. This opens a race if another signal is made pending before the system call instruction can be reexecuted. The original system call will be restarted even if the second signal would have ended the system call with -EINTR. These two issues can be solved by dropping the early rewind of the system call before get_signal_to_deliver has been called and by using the TIF_RESTART_SVC magic to do the restart if no signal has to be delivered. The only situation where the system call restart via the repeat of the svc instruction is appropriate is when a SA_RESTART signal is delivered to user space. Unfortunately this breaks inferior calls by the debugger again. The system call number and the length of the system call instruction is lost over the inferior call and user space will see ERESTARTNOHAND/ ERESTARTSYS/ERESTARTNOINTR/ERESTART_RESTARTBLOCK. To correct this a new ptrace interface is added to save/restore the system call number and system call instruction length. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2011-10-30 15:16:47 +01:00
/* fallthrough */
case -ERESTARTNOHAND:
case -ERESTARTSYS:
case -ERESTARTNOINTR:
/* Restart system call with magic TIF bit. */
regs->gprs[2] = regs->orig_gpr2;
set_thread_flag(TIF_SYSCALL);
if (test_thread_flag(TIF_SINGLE_STEP))
set_thread_flag(TIF_PER_TRAP);
break;
[S390] signal race with restarting system calls For a ERESTARTNOHAND/ERESTARTSYS/ERESTARTNOINTR restarting system call do_signal will prepare the restart of the system call with a rewind of the PSW before calling get_signal_to_deliver (where the debugger might take control). For A ERESTART_RESTARTBLOCK restarting system call do_signal will set -EINTR as return code. There are two issues with this approach: 1) strace never sees ERESTARTNOHAND, ERESTARTSYS, ERESTARTNOINTR or ERESTART_RESTARTBLOCK as the rewinding already took place or the return code has been changed to -EINTR 2) if get_signal_to_deliver does not return with a signal to deliver the restart via the repeat of the svc instruction is left in place. This opens a race if another signal is made pending before the system call instruction can be reexecuted. The original system call will be restarted even if the second signal would have ended the system call with -EINTR. These two issues can be solved by dropping the early rewind of the system call before get_signal_to_deliver has been called and by using the TIF_RESTART_SVC magic to do the restart if no signal has to be delivered. The only situation where the system call restart via the repeat of the svc instruction is appropriate is when a SA_RESTART signal is delivered to user space. Unfortunately this breaks inferior calls by the debugger again. The system call number and the length of the system call instruction is lost over the inferior call and user space will see ERESTARTNOHAND/ ERESTARTSYS/ERESTARTNOINTR/ERESTART_RESTARTBLOCK. To correct this a new ptrace interface is added to save/restore the system call number and system call instruction length. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2011-10-30 15:16:47 +01:00
}
}
/*
* If there's no signal to deliver, we just put the saved sigmask back.
*/
restore_saved_sigmask();
}
void do_notify_resume(struct pt_regs *regs)
{
clear_thread_flag(TIF_NOTIFY_RESUME);
tracehook_notify_resume(regs);
}