power: supply: cpcap-battery: Fix low battery check
We need to check current instead of the charge counter to see if a charger is connected. The charge counter shows the cumulated value instead of the current charge current and can be negative or positive. Cc: Pavel Machek <pavel@ucw.cz> Signed-off-by: Tony Lindgren <tony@atomide.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
parent
6f76aa94e1
commit
1a9aadc86a
|
@ -562,11 +562,11 @@ static irqreturn_t cpcap_battery_irq_thread(int irq, void *data)
|
|||
|
||||
switch (d->action) {
|
||||
case CPCAP_BATTERY_IRQ_ACTION_BATTERY_LOW:
|
||||
if (latest->counter_uah >= 0)
|
||||
if (latest->current_ua >= 0)
|
||||
dev_warn(ddata->dev, "Battery low at 3.3V!\n");
|
||||
break;
|
||||
case CPCAP_BATTERY_IRQ_ACTION_POWEROFF:
|
||||
if (latest->counter_uah >= 0) {
|
||||
if (latest->current_ua >= 0) {
|
||||
dev_emerg(ddata->dev,
|
||||
"Battery empty at 3.1V, powering off\n");
|
||||
orderly_poweroff(true);
|
||||
|
|