thermal: armada: Add generic infrastructure to handle the sensor

In order to support similar SoC where the sensor value and valid
bit can have different shifts and/or mask, we add such fields to the
per-variant structure, instead of having the values hardcoded.

Acked-by: Jason Cooper <jason@lakedaemon.net>
Signed-off-by: Ezequiel Garcia <ezequiel.garcia@free-electrons.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This commit is contained in:
Ezequiel Garcia 2014-05-06 13:59:47 -03:00 committed by Zhang Rui
parent 9484bc62ca
commit 1fcacca40a
1 changed files with 12 additions and 5 deletions

View File

@ -24,10 +24,7 @@
#include <linux/of_device.h>
#include <linux/thermal.h>
#define THERMAL_VALID_OFFSET 9
#define THERMAL_VALID_MASK 0x1
#define THERMAL_TEMP_OFFSET 10
#define THERMAL_TEMP_MASK 0x1ff
/* Thermal Manager Control and Status Register */
#define PMU_TDC0_SW_RST_MASK (0x1 << 1)
@ -58,6 +55,11 @@ struct armada_thermal_data {
unsigned long coef_b;
unsigned long coef_m;
unsigned long coef_div;
/* Register shift and mask to access the sensor temperature */
unsigned int temp_shift;
unsigned int temp_mask;
unsigned int is_valid_shift;
};
static void armadaxp_init_sensor(struct armada_thermal_priv *priv)
@ -108,7 +110,7 @@ static bool armada_is_valid(struct armada_thermal_priv *priv)
{
unsigned long reg = readl_relaxed(priv->sensor);
return (reg >> THERMAL_VALID_OFFSET) & THERMAL_VALID_MASK;
return (reg >> priv->data->is_valid_shift) & THERMAL_VALID_MASK;
}
static int armada_get_temp(struct thermal_zone_device *thermal,
@ -126,7 +128,7 @@ static int armada_get_temp(struct thermal_zone_device *thermal,
}
reg = readl_relaxed(priv->sensor);
reg = (reg >> THERMAL_TEMP_OFFSET) & THERMAL_TEMP_MASK;
reg = (reg >> priv->data->temp_shift) & priv->data->temp_mask;
/* Get formula coeficients */
b = priv->data->coef_b;
@ -143,6 +145,8 @@ static struct thermal_zone_device_ops ops = {
static const struct armada_thermal_data armadaxp_data = {
.init_sensor = armadaxp_init_sensor,
.temp_shift = 10,
.temp_mask = 0x1ff,
.coef_b = 3153000000UL,
.coef_m = 10000000UL,
.coef_div = 13825,
@ -151,6 +155,9 @@ static const struct armada_thermal_data armadaxp_data = {
static const struct armada_thermal_data armada370_data = {
.is_valid = armada_is_valid,
.init_sensor = armada370_init_sensor,
.is_valid_shift = 9,
.temp_shift = 10,
.temp_mask = 0x1ff,
.coef_b = 3153000000UL,
.coef_m = 10000000UL,
.coef_div = 13825,