iio: light: vcnl4000: update sampling periods for vcnl4040
Vishay has published a new version of "Designing the VCNL4200 Into an
Application" application note in October 2019. The new version specifies
that there is +-20% of part to part tolerance. Although the application
note is related to vcnl4200, according to support the vcnl4040's "ASIC
is quite similar to that one for the VCNL4200".
So update the sampling periods (and comment), including the correct
sampling period for proximity. Both sampling periods are lower. Users
relying on the blocking behaviour of reading will get proximity
measurements much earlier.
Fixes: 5a441aade5
("iio: light: vcnl4000 add support for the VCNL4040 proximity and light sensor")
Reviewed-by: Guido Günther <agx@sigxcpu.org>
Tested-by: Guido Günther <agx@sigxcpu.org>
Signed-off-by: Tomas Novotny <tomas@novotny.cz>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
b42aa97ed5
commit
2ca5a8792d
|
@ -174,9 +174,10 @@ static int vcnl4200_init(struct vcnl4000_data *data)
|
|||
data->al_scale = 24000;
|
||||
break;
|
||||
case VCNL4040_PROD_ID:
|
||||
/* Integration time is 80ms, add 10ms. */
|
||||
data->vcnl4200_al.sampling_rate = ktime_set(0, 100000 * 1000);
|
||||
data->vcnl4200_ps.sampling_rate = ktime_set(0, 100000 * 1000);
|
||||
/* Default wait time is 80ms, add 20% tolerance. */
|
||||
data->vcnl4200_al.sampling_rate = ktime_set(0, 96000 * 1000);
|
||||
/* Default wait time is 5ms, add 20% tolerance. */
|
||||
data->vcnl4200_ps.sampling_rate = ktime_set(0, 6000 * 1000);
|
||||
data->al_scale = 120000;
|
||||
break;
|
||||
}
|
||||
|
|
Loading…
Reference in New Issue