ALSA: oxygen: modify the SPI writing function

Modify the oxygen_write_spi() function to use the newly
introduced oxygen_wait_spi() function. Change return value
from void to int, so it can return error codes. Older
drivers just ignore that return value, new drivers can
check this value. We need to wait AFTER
initiating the SPI transaction, otherwise read
operation will not work.

Signed-off-by: Roman Volkov <v1ron@mail.ru>
Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
This commit is contained in:
Roman Volkov 2014-01-24 16:18:03 +04:00 committed by Clemens Ladisch
parent 10dd44dc88
commit 303cff30d3
2 changed files with 7 additions and 12 deletions

View File

@ -198,7 +198,7 @@ void oxygen_write_ac97(struct oxygen *chip, unsigned int codec,
void oxygen_write_ac97_masked(struct oxygen *chip, unsigned int codec,
unsigned int index, u16 data, u16 mask);
void oxygen_write_spi(struct oxygen *chip, u8 control, unsigned int data);
int oxygen_write_spi(struct oxygen *chip, u8 control, unsigned int data);
void oxygen_write_i2c(struct oxygen *chip, u8 device, u8 map, u8 data);
void oxygen_reset_uart(struct oxygen *chip);

View File

@ -212,23 +212,18 @@ static int oxygen_wait_spi(struct oxygen *chip)
return -EIO;
}
void oxygen_write_spi(struct oxygen *chip, u8 control, unsigned int data)
int oxygen_write_spi(struct oxygen *chip, u8 control, unsigned int data)
{
unsigned int count;
/* should not need more than 30.72 us (24 * 1.28 us) */
count = 10;
while ((oxygen_read8(chip, OXYGEN_SPI_CONTROL) & OXYGEN_SPI_BUSY)
&& count > 0) {
udelay(4);
--count;
}
/*
* We need to wait AFTER initiating the SPI transaction,
* otherwise read operations will not work.
*/
oxygen_write8(chip, OXYGEN_SPI_DATA1, data);
oxygen_write8(chip, OXYGEN_SPI_DATA2, data >> 8);
if (control & OXYGEN_SPI_DATA_LENGTH_3)
oxygen_write8(chip, OXYGEN_SPI_DATA3, data >> 16);
oxygen_write8(chip, OXYGEN_SPI_CONTROL, control);
return oxygen_wait_spi(chip);
}
EXPORT_SYMBOL(oxygen_write_spi);