[PATCH] s390: hangcheck timer support

Remove useless s390 define from hangcheck-timer, remove wrong definition of a
TOD second and other s390 ifdefs.  Use monotonic_clock instead.

Add hangcheck-timer option, copied from drivers/char/Kconfig.  This is ugly
but unless we have a big Kconfig cleanup we cannot include
drivers/char/Kconfig...

Signed-off-by: Jan Glauber <jan.glauber@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
This commit is contained in:
Jan Glauber 2006-02-01 03:06:34 -08:00 committed by Linus Torvalds
parent 32f65f2746
commit 3633b0475e
3 changed files with 9 additions and 12 deletions

View File

@ -992,7 +992,7 @@ config HPET_MMAP
config HANGCHECK_TIMER
tristate "Hangcheck timer"
depends on X86 || IA64 || PPC64 || S390
depends on X86 || IA64 || PPC64
help
The hangcheck-timer module detects when the system has gone
out to lunch past a certain margin. It can reboot the system

View File

@ -117,12 +117,9 @@ __setup("hcheck_reboot", hangcheck_parse_reboot);
__setup("hcheck_dump_tasks", hangcheck_parse_dump_tasks);
#endif /* not MODULE */
#if defined(CONFIG_X86)
#if defined(CONFIG_X86) || defined(CONFIG_S390)
# define HAVE_MONOTONIC
# define TIMER_FREQ 1000000000ULL
#elif defined(CONFIG_S390)
/* FA240000 is 1 Second in the IBM time universe (Page 4-38 Principles of Op for zSeries */
# define TIMER_FREQ 0xFA240000ULL
#elif defined(CONFIG_IA64)
# define TIMER_FREQ ((unsigned long long)local_cpu_data->itc_freq)
#elif defined(CONFIG_PPC64)
@ -134,12 +131,7 @@ extern unsigned long long monotonic_clock(void);
#else
static inline unsigned long long monotonic_clock(void)
{
# ifdef __s390__
/* returns the TOD. see 4-38 Principles of Op of zSeries */
return get_clock();
# else
return get_cycles();
# endif /* __s390__ */
}
#endif /* HAVE_MONOTONIC */
@ -188,8 +180,6 @@ static int __init hangcheck_init(void)
VERSION_STR, hangcheck_tick, hangcheck_margin);
#if defined (HAVE_MONOTONIC)
printk("Hangcheck: Using monotonic_clock().\n");
#elif defined(__s390__)
printk("Hangcheck: Using TOD.\n");
#else
printk("Hangcheck: Using get_cycles().\n");
#endif /* HAVE_MONOTONIC */

View File

@ -51,6 +51,13 @@ config UNIX98_PTY_COUNT
When not in use, each additional set of 256 PTYs occupy
approximately 8 KB of kernel memory on 32-bit architectures.
config HANGCHECK_TIMER
tristate "Hangcheck timer"
help
The hangcheck-timer module detects when the system has gone
out to lunch past a certain margin. It can reboot the system
or merely print a warning.
source "drivers/char/watchdog/Kconfig"
comment "S/390 character device drivers"