power: supply: cpcap-battery: Use accumulator for current and power average

We should not use measured current value for average since we have proper
coulomb counter values available. Using measured current value should
be only used when the value is queried at a higher rate than the 250 ms
rate the coulomb counter is configured to run at.

Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
Tony Lindgren 2019-04-07 11:12:52 -07:00 committed by Sebastian Reichel
parent 35439b7ab2
commit 5fc27a5419
1 changed files with 4 additions and 4 deletions

View File

@ -476,11 +476,11 @@ static int cpcap_battery_get_property(struct power_supply *psy,
val->intval = ddata->config.info.voltage_min_design;
break;
case POWER_SUPPLY_PROP_CURRENT_AVG:
if (cached) {
sample = latest->cc.sample - previous->cc.sample;
if (!sample) {
val->intval = cpcap_battery_cc_get_avg_current(ddata);
break;
}
sample = latest->cc.sample - previous->cc.sample;
accumulator = latest->cc.accumulator - previous->cc.accumulator;
val->intval = cpcap_battery_cc_to_ua(ddata, sample,
accumulator,
@ -497,13 +497,13 @@ static int cpcap_battery_get_property(struct power_supply *psy,
val->intval = div64_s64(tmp, 100);
break;
case POWER_SUPPLY_PROP_POWER_AVG:
if (cached) {
sample = latest->cc.sample - previous->cc.sample;
if (!sample) {
tmp = cpcap_battery_cc_get_avg_current(ddata);
tmp *= (latest->voltage / 10000);
val->intval = div64_s64(tmp, 100);
break;
}
sample = latest->cc.sample - previous->cc.sample;
accumulator = latest->cc.accumulator - previous->cc.accumulator;
tmp = cpcap_battery_cc_to_ua(ddata, sample, accumulator,
latest->cc.offset);