From b98467fe96d2415836d154ecfe1cd389bf4147b5 Mon Sep 17 00:00:00 2001 From: Peter Ujfalusi Date: Thu, 29 Oct 2020 12:03:35 +0200 Subject: [PATCH] thermal: ti-soc-thermal: Disable the CPU PM notifier for OMAP4430 It has been observed that on OMAP4430 (ES2.0, ES2.1 and ES2.3) the enabled notifier causes errors on the DTEMP readout values: ti-soc-thermal 4a002260.bandgap: in range ADC val: 52 ti-soc-thermal 4a002260.bandgap: in range ADC val: 64 ti-soc-thermal 4a002260.bandgap: in range ADC val: 64 ti-soc-thermal 4a002260.bandgap: out of range ADC val: 0 thermal thermal_zone0: failed to read out thermal zone (-5) ti-soc-thermal 4a002260.bandgap: out of range ADC val: 0 thermal thermal_zone0: failed to read out thermal zone (-5) ti-soc-thermal 4a002260.bandgap: out of range ADC val: 4 thermal thermal_zone0: failed to read out thermal zone (-5) ti-soc-thermal 4a002260.bandgap: in range ADC val: 100 raw 100 translates to 133 Celsius on omap4-sdp, triggering shutdown due to critical temperature. When the notifier is disable for OMAP4430 the DTEMP values are stable: ti-soc-thermal 4a002260.bandgap: in range ADC val: 56 ti-soc-thermal 4a002260.bandgap: in range ADC val: 56 ti-soc-thermal 4a002260.bandgap: in range ADC val: 57 ti-soc-thermal 4a002260.bandgap: in range ADC val: 57 ti-soc-thermal 4a002260.bandgap: in range ADC val: 56 Fixes: 5093402e5b44 ("thermal: ti-soc-thermal: Enable addition power management") Signed-off-by: Peter Ujfalusi Tested-by: Tony Lindgren Acked-by: Keerthy Signed-off-by: Daniel Lezcano Link: https://lore.kernel.org/r/20201029100335.27665-1-peter.ujfalusi@ti.com --- drivers/thermal/ti-soc-thermal/ti-bandgap.c | 18 ++++++++++++++++-- 1 file changed, 16 insertions(+), 2 deletions(-) diff --git a/drivers/thermal/ti-soc-thermal/ti-bandgap.c b/drivers/thermal/ti-soc-thermal/ti-bandgap.c index 5e596168ba73..dcac99f327b0 100644 --- a/drivers/thermal/ti-soc-thermal/ti-bandgap.c +++ b/drivers/thermal/ti-soc-thermal/ti-bandgap.c @@ -20,6 +20,7 @@ #include #include #include +#include #include #include #include @@ -864,6 +865,17 @@ static struct ti_bandgap *ti_bandgap_build(struct platform_device *pdev) return bgp; } +/* + * List of SoCs on which the CPU PM notifier can cause erros on the DTEMP + * readout. + * Enabled notifier on these machines results in erroneous, random values which + * could trigger unexpected thermal shutdown. + */ +static const struct soc_device_attribute soc_no_cpu_notifier[] = { + { .machine = "OMAP4430" }, + { /* sentinel */ }, +}; + /*** Device driver call backs ***/ static @@ -1020,7 +1032,8 @@ int ti_bandgap_probe(struct platform_device *pdev) #ifdef CONFIG_PM_SLEEP bgp->nb.notifier_call = bandgap_omap_cpu_notifier; - cpu_pm_register_notifier(&bgp->nb); + if (!soc_device_match(soc_no_cpu_notifier)) + cpu_pm_register_notifier(&bgp->nb); #endif return 0; @@ -1056,7 +1069,8 @@ int ti_bandgap_remove(struct platform_device *pdev) struct ti_bandgap *bgp = platform_get_drvdata(pdev); int i; - cpu_pm_unregister_notifier(&bgp->nb); + if (!soc_device_match(soc_no_cpu_notifier)) + cpu_pm_unregister_notifier(&bgp->nb); /* Remove sensor interfaces */ for (i = 0; i < bgp->conf->sensor_count; i++) {