ntb_hw_switchtec: debug print 64bit aligned crosslink BAR Numbers

Switchtec NTB crosslink BARs are 64bit addressed but they are printed as
32bit addressed BARs. Fix debug log to increment the BAR numbers by 2 to
reflect the 64bit address alignment.

Fixes: 0175250182 ("ntb_hw_switchtec: Add initialization code for crosslink")
Signed-off-by: Paul Selles <paul.selles@microchip.com>
Signed-off-by: Wesley Sheng <wesley.sheng@microchip.com>
Reviewed-by: Logan Gunthorpe <logang@deltatee.com>
Signed-off-by: Jon Mason <jdmason@kudzu.us>
This commit is contained in:
Paul Selles 2018-12-06 21:30:50 +08:00 committed by Jon Mason
parent bfeffd1552
commit cce8e04cf7
1 changed files with 1 additions and 1 deletions

View File

@ -1120,7 +1120,7 @@ static int crosslink_enum_partition(struct switchtec_ntb *sndev,
dev_dbg(&sndev->stdev->dev, dev_dbg(&sndev->stdev->dev,
"Crosslink BAR%d addr: %llx\n", "Crosslink BAR%d addr: %llx\n",
i, bar_addr); i*2, bar_addr);
if (bar_addr != bar_space * i) if (bar_addr != bar_space * i)
continue; continue;