clocksource: davinci: only enable clockevents once tim34 is initialized
The DM365 platform has a strange quirk (only present when using ancient u-boot - mainline u-boot v2013.01 and later works fine) where if we enable the second half of the timer in periodic mode before we do its initialization - the time won't start flowing and we can't boot. When using more recent u-boot, we can enable the timer, then reinitialize it and all works fine. To work around this issue only enable clockevents once tim34 is initialized i.e. move clockevents_config_and_register() below tim34 initialization. Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com> Signed-off-by: Sekhar Nori <nsekhar@ti.com>
This commit is contained in:
parent
e42617b825
commit
cea931c251
@ -302,10 +302,6 @@ int __init davinci_timer_register(struct clk *clk,
|
||||
return rv;
|
||||
}
|
||||
|
||||
clockevents_config_and_register(&clockevent->dev, tick_rate,
|
||||
DAVINCI_TIMER_MIN_DELTA,
|
||||
DAVINCI_TIMER_MAX_DELTA);
|
||||
|
||||
davinci_clocksource.dev.rating = 300;
|
||||
davinci_clocksource.dev.read = davinci_clocksource_read;
|
||||
davinci_clocksource.dev.mask =
|
||||
@ -323,6 +319,10 @@ int __init davinci_timer_register(struct clk *clk,
|
||||
davinci_clocksource_init_tim34(base);
|
||||
}
|
||||
|
||||
clockevents_config_and_register(&clockevent->dev, tick_rate,
|
||||
DAVINCI_TIMER_MIN_DELTA,
|
||||
DAVINCI_TIMER_MAX_DELTA);
|
||||
|
||||
rv = clocksource_register_hz(&davinci_clocksource.dev, tick_rate);
|
||||
if (rv) {
|
||||
pr_err("Unable to register clocksource");
|
||||
|
Loading…