net: dsa: sja1105: Remove restriction of zero base-time for taprio offload

The check originates from the initial implementation which was not based
on PTP time but on a standalone clock source. In the meantime we can now
program the PTPSCHTM register at runtime with the dynamic base time
(actually with a value that is 200 ns smaller, to avoid writing DELTA=0
in the Schedule Entry Points Parameters Table). And we also have logic
for moving the actual base time in the future of the PHC's current time
base, so the check for zero serves no purpose, since even if the user
will specify zero, that's not what will end up in the static config
table where the limitation is.

Fixes: 86db36a347 ("net: dsa: sja1105: Implement state machine for TAS with PTP clock source")
Signed-off-by: Vladimir Oltean <olteanv@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Vladimir Oltean 2019-12-27 03:03:54 +02:00 committed by David S. Miller
parent 5a47f588ee
commit d00bdc0a88
1 changed files with 0 additions and 5 deletions

View File

@ -477,11 +477,6 @@ int sja1105_setup_tc_taprio(struct dsa_switch *ds, int port,
if (admin->cycle_time_extension)
return -ENOTSUPP;
if (!ns_to_sja1105_delta(admin->base_time)) {
dev_err(ds->dev, "A base time of zero is not hardware-allowed\n");
return -ERANGE;
}
for (i = 0; i < admin->num_entries; i++) {
s64 delta_ns = admin->entries[i].interval;
s64 delta_cycles = ns_to_sja1105_delta(delta_ns);