mmc: mmci: Remove redundant runtime PM calls

Commit 9250aea76b ("mmc: core: Enable runtime PM management of host
devices"), made some calls to the runtime PM API from the driver
redundant. Especially those which deals with runtime PM reference
counting, so let's remove them.

Cc: Russell King <linux@arm.linux.org.uk>
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
This commit is contained in:
Ulf Hansson 2016-03-21 14:17:00 +01:00
parent bc94440d4e
commit d8b7d6b7f9
1 changed files with 0 additions and 20 deletions

View File

@ -226,16 +226,11 @@ static int mmci_card_busy(struct mmc_host *mmc)
unsigned long flags;
int busy = 0;
pm_runtime_get_sync(mmc_dev(mmc));
spin_lock_irqsave(&host->lock, flags);
if (readl(host->base + MMCISTATUS) & MCI_ST_CARDBUSY)
busy = 1;
spin_unlock_irqrestore(&host->lock, flags);
pm_runtime_mark_last_busy(mmc_dev(mmc));
pm_runtime_put_autosuspend(mmc_dev(mmc));
return busy;
}
@ -381,9 +376,6 @@ mmci_request_end(struct mmci_host *host, struct mmc_request *mrq)
host->cmd = NULL;
mmc_request_done(host->mmc, mrq);
pm_runtime_mark_last_busy(mmc_dev(host->mmc));
pm_runtime_put_autosuspend(mmc_dev(host->mmc));
}
static void mmci_set_mask1(struct mmci_host *host, unsigned int mask)
@ -1290,8 +1282,6 @@ static void mmci_request(struct mmc_host *mmc, struct mmc_request *mrq)
return;
}
pm_runtime_get_sync(mmc_dev(mmc));
spin_lock_irqsave(&host->lock, flags);
host->mrq = mrq;
@ -1318,8 +1308,6 @@ static void mmci_set_ios(struct mmc_host *mmc, struct mmc_ios *ios)
unsigned long flags;
int ret;
pm_runtime_get_sync(mmc_dev(mmc));
if (host->plat->ios_handler &&
host->plat->ios_handler(mmc_dev(mmc), ios))
dev_err(mmc_dev(mmc), "platform ios_handler failed\n");
@ -1414,9 +1402,6 @@ static void mmci_set_ios(struct mmc_host *mmc, struct mmc_ios *ios)
mmci_reg_delay(host);
spin_unlock_irqrestore(&host->lock, flags);
pm_runtime_mark_last_busy(mmc_dev(mmc));
pm_runtime_put_autosuspend(mmc_dev(mmc));
}
static int mmci_get_cd(struct mmc_host *mmc)
@ -1440,8 +1425,6 @@ static int mmci_sig_volt_switch(struct mmc_host *mmc, struct mmc_ios *ios)
if (!IS_ERR(mmc->supply.vqmmc)) {
pm_runtime_get_sync(mmc_dev(mmc));
switch (ios->signal_voltage) {
case MMC_SIGNAL_VOLTAGE_330:
ret = regulator_set_voltage(mmc->supply.vqmmc,
@ -1459,9 +1442,6 @@ static int mmci_sig_volt_switch(struct mmc_host *mmc, struct mmc_ios *ios)
if (ret)
dev_warn(mmc_dev(mmc), "Voltage switch failed\n");
pm_runtime_mark_last_busy(mmc_dev(mmc));
pm_runtime_put_autosuspend(mmc_dev(mmc));
}
return ret;