[media] [PATH,1/2] mxl5007 move reset to attach
This patch move the soft reset to the attach function because with dual tuners, when one tuner do reset, the other one is perturbed, and the stream has errors. Signed-off-by: Jose Alberto Reguero <jareguero@telefonica.net> Reviewed-by: Antti Palosaari <crope@iki.fi> Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
This commit is contained in:
parent
47a09af68b
commit
fe4860af00
@ -531,10 +531,6 @@ static int mxl5007t_tuner_init(struct mxl5007t_state *state,
|
||||
struct reg_pair_t *init_regs;
|
||||
int ret;
|
||||
|
||||
ret = mxl5007t_soft_reset(state);
|
||||
if (mxl_fail(ret))
|
||||
goto fail;
|
||||
|
||||
/* calculate initialization reg array */
|
||||
init_regs = mxl5007t_calc_init_regs(state, mode);
|
||||
|
||||
@ -900,7 +896,20 @@ struct dvb_frontend *mxl5007t_attach(struct dvb_frontend *fe,
|
||||
/* existing tuner instance */
|
||||
break;
|
||||
}
|
||||
|
||||
if (fe->ops.i2c_gate_ctrl)
|
||||
fe->ops.i2c_gate_ctrl(fe, 1);
|
||||
|
||||
ret = mxl5007t_soft_reset(state);
|
||||
|
||||
if (fe->ops.i2c_gate_ctrl)
|
||||
fe->ops.i2c_gate_ctrl(fe, 0);
|
||||
|
||||
if (mxl_fail(ret))
|
||||
goto fail;
|
||||
|
||||
fe->tuner_priv = state;
|
||||
|
||||
mutex_unlock(&mxl5007t_list_mutex);
|
||||
|
||||
memcpy(&fe->ops.tuner_ops, &mxl5007t_tuner_ops,
|
||||
|
Loading…