In the case where we have more than one volumes on different UBI
devices, it may be not that easy to tell which volume prints the
messages. Add ubi number and volume id in ubifs_msg/warn/error
to help debug. These two values are passed by struct ubifs_info.
For those where ubifs_info is not initialized yet, ubifs_* is
replaced by pr_*. For those where ubifs_info is not avaliable,
ubifs_info is passed to the calling function as a const parameter.
The output looks like,
[ 95.444879] UBIFS (ubi0:1): background thread "ubifs_bgt0_1" started, PID 696
[ 95.484688] UBIFS (ubi0:1): UBIFS: mounted UBI device 0, volume 1, name "test1"
[ 95.484694] UBIFS (ubi0:1): LEB size: 126976 bytes (124 KiB), min./max. I/O unit sizes: 2048 bytes/2048 bytes
[ 95.484699] UBIFS (ubi0:1): FS size: 30220288 bytes (28 MiB, 238 LEBs), journal size 1523712 bytes (1 MiB, 12 LEBs)
[ 95.484703] UBIFS (ubi0:1): reserved for root: 1427378 bytes (1393 KiB)
[ 95.484709] UBIFS (ubi0:1): media format: w4/r0 (latest is w4/r0), UUID 40DFFC0E-70BE-4193-8905-F7D6DFE60B17, small LPT model
[ 95.489875] UBIFS (ubi1:0): background thread "ubifs_bgt1_0" started, PID 699
[ 95.529713] UBIFS (ubi1:0): UBIFS: mounted UBI device 1, volume 0, name "test2"
[ 95.529718] UBIFS (ubi1:0): LEB size: 126976 bytes (124 KiB), min./max. I/O unit sizes: 2048 bytes/2048 bytes
[ 95.529724] UBIFS (ubi1:0): FS size: 19808256 bytes (18 MiB, 156 LEBs), journal size 1015809 bytes (0 MiB, 8 LEBs)
[ 95.529727] UBIFS (ubi1:0): reserved for root: 935592 bytes (913 KiB)
[ 95.529733] UBIFS (ubi1:0): media format: w4/r0 (latest is w4/r0), UUID EEB7779D-F419-4CA9-811B-831CAC7233D4, small LPT model
[ 954.264767] UBIFS error (ubi1:0 pid 756): ubifs_read_node: bad node type (255 but expected 6)
[ 954.367030] UBIFS error (ubi1:0 pid 756): ubifs_read_node: bad node at LEB 0:0, LEB mapping status 1
Signed-off-by: Sheng Yong <shengyong1@huawei.com>
Signed-off-by: Artem Bityutskiy <artem.bityutskiy@linux.intel.com>
fs/ubifs/compress.c:111:8: warning: incorrect type in argument 5 (different signedness)
fs/ubifs/compress.c:111:8: expected unsigned int *dlen
fs/ubifs/compress.c:111:8: got int *out_len
fs/ubifs/compress.c:175:10: warning: incorrect type in argument 5 (different signedness)
fs/ubifs/compress.c:175:10: expected unsigned int *dlen
fs/ubifs/compress.c:175:10: got int *out_len
Fix this by adding a cast to (unsigned int *). We guarantee that
our lengths are small and no overflow is possible.
Signed-off-by: Artem Bityutskiy <Artem.Bityutskiy@nokia.com>
This patch fixes the following section mismatch:
WARNING: fs/ubifs/ubifs.o(.init.text+0xec): Section mismatch in reference from the function init_module() to the function .exit.text:ubifs_compressors_exit()
Signed-off-by: Artem Bityutskiy <Artem.Bityutskiy@nokia.com>
It is very handy to be able to change default UBIFS compressor
via mount options. Introduce -o compr=<name> mount option support.
Currently only "none", "lzo" and "zlib" compressors are supported.
Signed-off-by: Artem Bityutskiy <Artem.Bityutskiy@nokia.com>
If data does not compress, it is better to leave it uncompressed
because we'll read it faster then. So do not compress data if we
save less than 64 bytes.
Signed-off-by: Artem Bityutskiy <Artem.Bityutskiy@nokia.com>
Update the comment for ubifs_compress(), which incorrectly states that it
returnsa success/failure indicator.
Signed-off-by: Geert Uytterhoeven <Geert.Uytterhoeven@sonycom.com>
Signed-off-by: Artem Bityutskiy <Artem.Bityutskiy@nokia.com>
This is a new flash file system. See
http://www.linux-mtd.infradead.org/doc/ubifs.html
Signed-off-by: Artem Bityutskiy <Artem.Bityutskiy@nokia.com>
Signed-off-by: Adrian Hunter <ext-adrian.hunter@nokia.com>