Commit Graph

679045 Commits

Author SHA1 Message Date
Christoph Hellwig 39bdc5901f nvme: no need to wait for the reset when keepalive fails
We don't need to wait for the reset from the delayed work item that
is kicked off when we don't get a keepalive.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reported-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
2017-06-15 15:48:45 +02:00
Christoph Hellwig d86c4d8ef3 nvme: move reset workqueue handling to common code
This moves the nvme_reset function from the PCIe driver to common code,
renaming it to nvme_reset_ctrl in the process.  Additionally a new
helper nvme_reset_ctrl_sync is added for the case where we want to
wait for the reset.  To facilitate that the reset_work work structure is
move to the common nvme_ctrl structure and the ->reset_ctrl method is
removed.  For now the drivers initialize the reset_work with their own
callback, but longer term we should move to callouts for specific
parts of the reset process and move even more code to the core.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
2017-06-15 15:48:34 +02:00
Christoph Hellwig 0350815a90 nvme-pci: merge init_request methods
Now that we get the tagset passed we can have a single implementation for
the I/O and admin queues.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Max Gurtovoy <maxg@mellanox.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:35 +02:00
Christoph Hellwig 62b83b1834 nvme-loop: merge init_request methods
Now that we get the tagset passed we can have a single implementation for
the I/O and admin queues.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Max Gurtovoy <maxg@mellanox.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:33 +02:00
Christoph Hellwig 76f983cb79 nvme-fc: merge init_request methods
Now that we get the tagset passed we can have a single implementation for
the I/O and admin queues.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Max Gurtovoy <maxg@mellanox.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:32 +02:00
Christoph Hellwig 385475ee2d nvme-rdma: merge init_request and exit_request methods
Now that we get the tagset passed we can have a single implementation for
the I/O and admin queues.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Max Gurtovoy <maxg@mellanox.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:31 +02:00
Christoph Hellwig ebe6d874cd nvme: move protection information check into nvme_setup_rw
It only applies to read/write commands, and this way non-PCIe drivers
get the check as well instead of having to duplicate it when adding
metadata support.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <keith.busch@intel.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:30 +02:00
Christoph Hellwig b3b1b0b01d nvme: mark shutdown_timeout static
And open code the SHUTDOWN_TIMEOUT macro.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:29 +02:00
Dan Carpenter bb472baa23 nvme-rdma: fix error code in nvme_rdma_create_ctrl()
We accidentally return ERR_PTR(0) which is NULL.  The caller isn't
explicitly checking for that but I couldn't immediately spot whether
this would lead to a NULL dereference.  Anyway, we can fix add an
error code easily enough.

Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:28 +02:00
Guan Junxiong 97ddc36e4e nvmf: keep track of nvmet connect error status
To let the host know what happends to the connection establishment,
adjust the behavior of nvmf_log_connect_error to make more connect
specifig error codes human-readble.

Signed-off-by: Guan Junxiong <guanjunxiong@huawei.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:27 +02:00
Guan Junxiong 435e809058 nvme: add fields into identify controller data structure
Add the new to NVMe 1.3 fields EDSTT, DSTO, FWUG, HCTMA, MNTMT, MXTMT,
and SANICAP into the idenfity controller data structure.

Signed-off-by: Guan Junxiong <guanjunxiong@huawei.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:26 +02:00
Bart Van Assche 1b63327734 nvmet-fc: Remove a set-but-not-used variable
This was detected by building the nvmet-fc driver with W=1.

Signed-off-by: Bart Van Assche <bart.vanassche@sandisk.com>
Cc: James Smart <james.smart@broadcom.com>
Cc: Christoph Hellwig <hch@lst.de>
Cc: Johannes Thumshirn <jthumshirn@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:25 +02:00
Johannes Thumshirn f0425db00c nvme: use ctrl->device consistently for logging
Change the few left over users of ctrl->dev over to using ctrl->device
for logging purposes, so we consistently use the same device.

Signed-off-by: Johannes Thumshirn <jthumshirn@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:24 +02:00
Johannes Thumshirn c61d788b8b nvmet: allow overriding the NVMe VS via configfs
Allow overriding the announced NVMe Version of a via configfs.

This is particularly helpful when debugging new features for the host
or target side without bumping the hard coded version (as the target
might not be fully compliant to the announced version yet).

Signed-off-by: Johannes Thumshirn <jthumshirn@suse.de>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Reviewed-by: Guan Junxiong <guanjunxiong@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:23 +02:00
Johannes Thumshirn 430c7bef17 nvmet: add uuid field to nvme_ns and populate via configfs
Add the UUID field from the NVMe Namespace Identification Descriptor
to the nvmet_ns structure and allow it's population via configfs.

Signed-off-by: Johannes Thumshirn <jthumshirn@suse.de>
Reviewed-by: Max Gurtovoy <maxg@mellanox.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:22 +02:00
Johannes Thumshirn 637dc0f38a nvmet: implement namespace identify descriptor list
A NVMe Identify NS command with a CNS value of '3' is expecting a list
of Namespace Identification Descriptor structures to be returned to
the host for the namespace requested in the namespace identify
command.

This Namespace Identification Descriptor structure consists of the
type of the namespace identifier, the length of the identifier and the
actual identifier.

Valid types are NGUID and UUID which we have saved in our nvme_ns
structure if they have been configured via configfs. If no value has
been assigened to one of these we return an "invalid opcode" back to
the host to maintain backward compatibiliy with older implementations
without Namespace Identify Descriptor list support.

Also as the Namespace Identify Descriptor list is the only mandatory
feature change between 1.2.1 and 1.3 we can bump the advertised
version as well.

Signed-off-by: Johannes Thumshirn <jthumshirn@suse.de>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Reviewed-by: Max Gurtovoy <maxg@mellanox.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:21 +02:00
Johannes Thumshirn d934f9848a nvme: provide UUID value to userspace
Now that we have a way for getting the UUID from a target, provide it
to userspace as well.

Unfortunately there is already a sysfs attribute called UUID which is
a misnomer as it holds the NGUID value. So instead of creating yet
another wrong name, create a new 'nguid' sysfs attribute for the
NGUID. For the UUID attribute add a check wheter the namespace has a
UUID assigned to it and return this or return the NGUID to maintain
backwards compatibility. This should give userspace a chance to catch
up.

Signed-off-by: Johannes Thumshirn <jthumshirn@suse.de>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Reviewed-by: Sagi Grimberg <sagi@rimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:20 +02:00
Johannes Thumshirn 3b22ba2682 nvme: get list of namespace descriptors
If a target identifies itself as NVMe 1.3 compliant, try to get the
list of Namespace Identification Descriptors and populate the UUID,
NGUID and EUI64 fileds in the NVMe namespace structure with these
values.

Signed-off-by: Johannes Thumshirn <jthumshirn@suse.de>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:18 +02:00
Johannes Thumshirn 90985b84c4 nvme: rename uuid to nguid in nvme_ns
The uuid field in the nvme_ns structure represents the nguid field
from the identify namespace command. And as NVMe 1.3 introduced an
UUID in the NVMe Namespace Identification Descriptor this will
collide.

So rename the uuid to nguid to prevent any further
confusion. Unfortunately we export the nguid to sysfs in the uuid
sysfs attribute, but this can't be changed anymore without possibly
breaking existing userspace.

Signed-off-by: Johannes Thumshirn <jthumshirn@suse.de>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:17 +02:00
Johannes Thumshirn af8b86e9a7 nvme: introduce NVMe Namespace Identification Descriptor structures
Signed-off-by: Johannes Thumshirn <jthumshirn@suse.de>
Reviewed-by: Max Gurtovoy <maxg@mellanox.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:16 +02:00
Johannes Thumshirn 0add5e8e58 nvmet: use NVME_IDENTIFY_DATA_SIZE
Use NVME_IDENTIFY_DATA_SIZE define instead of hard coding the magic
4096 value.

Signed-off-by: Johannes Thumshirn <jthumshirn@suse.de>
Reviewed-by: Max Gurtovoy <maxg@mellanox.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Hannes Reinecke <hare@suse.com>
[hch: converted three more users]
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:15 +02:00
Johannes Thumshirn 0945e56994 scatterlist: add sg_zero_buffer() helper
The sg_zero_buffer() helper is used to zero fill an area in a SG
list.

Signed-off-by: Johannes Thumshirn <jthumshirn@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
[hch: renamed to sg_zero_buffer]
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:14 +02:00
Sagi Grimberg d19d4c8eb1 nvme-pci: remove redundant includes
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Max Gurtovoy <maxg@mellanox.com>
2017-06-15 14:30:13 +02:00
Keith Busch b2a0eb1a0a nvme-pci: Remove watchdog timer
The controller status polling was added to preemptively reset a failed
controller. This early detection would allow commands that would normally
timeout a chance for a retry, or find broken links when the platform
didn't support hotplug.

This once-per-second MMIO read, however, created more problems than
it solves. This often races with PCIe Hotplug events that required
complicated syncing between work queues, frequently triggered PCIe
Completion Timeout errors that also lead to fatal machine checks, and
unnecessarily disrupts low power modes by running on idle controllers.

This patch removes the watchdog timer, and instead checks controller
health only on an IO timeout when we have a reason to believe something
is wrong. If the controller is failed, the driver will disable immediately
and request scheduling a reset.

Suggested-by: Andy Lutomirski <luto@amacapital.net>
Signed-off-by: Keith Busch <keith.busch@intel.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:30:08 +02:00
Xu Yu 97f6ef6464 nvme-pci: remap BAR0 to cover admin CQ doorbell for large stride
The existing driver initially maps 8192 bytes of BAR0 which is
intended to cover doorbells of admin SQ and CQ. However, if a
large stride, e.g. 10, is used, the doorbell of admin CQ will
be out of 8192 bytes. Consequently, a page fault will be raised
when the admin CQ doorbell is accessed in nvme_configure_admin_queue().

This patch fixes this issue by remapping BAR0 before accessing
admin CQ doorbell if the initial mapping is not enough.

Signed-off-by: Xu Yu <yu.a.xu@intel.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:29:51 +02:00
Sagi Grimberg fdf9dfa850 nvme: move nr_reconnects to nvme_ctrl
It is not a user option but rather a variable controller
attribute.

Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:29:49 +02:00
Sagi Grimberg c669ccdc50 nvme: queue ns scanning and async request from nvme_wq
To suppress the warning triggered by nvme_uninit_ctrl:
kernel: [   50.350439] nvme nvme0: rescanning
kernel: [   50.363351] ------------[ cut here]------------
kernel: [   50.363396] WARNING: CPU: 1 PID: 37 at kernel/workqueue.c:2423 check_flush_dependency+0x11f/0x130
kernel: [   50.363409] workqueue: WQ_MEM_RECLAIM
nvme-wq:nvme_del_ctrl_work [nvme_core] is flushing !WQ_MEM_RECLAIM events:nvme_scan_work [nvme_core]

This was triggered with nvme-loop, but can happen with rdma/pci as well afaict.

Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:29:48 +02:00
Sagi Grimberg 9a6327d2f2 nvme: Move transports to use nvme-core workqueue
Instead of each transport using it's own workqueue, export
a single nvme-core workqueue and use that instead.

In the future, this will help us moving towards some unification
if controller setup/teardown flows.

Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:29:43 +02:00
Sagi Grimberg c58bd1bf4d nvme: Don't allow to reset a reconnecting controller
The reset operation is guaranteed to fail for all scenarios
but the esoteric case where in the last reconnect attempt
concurrent with the reset we happen to successfully reconnect.

We just deny initiating a reset if we are reconnecting.

Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:28:22 +02:00
Sagi Grimberg b282a88d91 nvme-rdma: Get rid of CONNECTED state
We only care about if the queue is LIVE for request submission,
so no need for CONNECTED.

Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:28:21 +02:00
Sagi Grimberg abf87d5e9d nvme-rdma: rework rdma connection establishment error path
Instead of introducing a flag for if the queue is allocated,
simply free the rdma resources when we get the error.

We allocate the queue rdma resources when we have an address
resolution, their we allocate (or take a reference on) our device
so we should free it when we have error after the address resolution
namely:
1. route resolution error
2. connect reject
3. connect error
4. peer unreachable error

Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:28:20 +02:00
Sagi Grimberg ca6e95bb0a nvme-rdma: make nvme_rdma_[create|destroy]_queue_ib symmetrical
We put the reference on the device in the destroy routine
so we should lookup and take the reference in the create
routine.

Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:28:19 +02:00
Sagi Grimberg c8295d1112 nvme-rdma: Don't rearm the CQ when polling directly
We don't need it as the core polling context will take
are of rearming the completion queue.

Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:28:18 +02:00
Sagi Grimberg dc5bc6a9fe nvme-rdma: Make queue flags bit numbers and not shifts
bitops accept bit numbers.

Reported-by: Vijay Immanuel <vijayi@attalasystems.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:28:17 +02:00
Sagi Grimberg 3dee63c7d9 nvme-rdma: get rid of unused ctrl lock
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:28:16 +02:00
Sagi Grimberg a29001c53a nvme-loop: get rid of unused controller lock
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2017-06-15 14:28:14 +02:00
Christoph Hellwig 87ad72a59a nvme-pci: implement host memory buffer support
If a controller supports the host memory buffer we try to provide
it with the requested size up to an upper cap set as a module
parameter.  We try to give as few as possible descriptors, eventually
working our way down.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <keith.busch@intel.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Max Gurtovoy <maxg@mellanox.com>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
2017-06-15 14:28:13 +02:00
Bart Van Assche dc9edc44de block: Fix a blk_exit_rl() regression
Avoid that the following complaint is reported:

 BUG: sleeping function called from invalid context at kernel/workqueue.c:2790
 in_atomic(): 1, irqs_disabled(): 0, pid: 41, name: rcuop/3
 1 lock held by rcuop/3/41:
  #0:  (rcu_callback){......}, at: [<ffffffff8111f9a2>] rcu_nocb_kthread+0x282/0x500
 Call Trace:
  dump_stack+0x86/0xcf
  ___might_sleep+0x174/0x260
  __might_sleep+0x4a/0x80
  flush_work+0x7e/0x2e0
  __cancel_work_timer+0x143/0x1c0
  cancel_work_sync+0x10/0x20
  blk_throtl_exit+0x25/0x60
  blkcg_exit_queue+0x35/0x40
  blk_release_queue+0x42/0x130
  kobject_put+0xa9/0x190

This happens since we invoke callbacks that need to block from the
queue release handler. Fix this by pushing the final release to
a workqueue.

Reported-by: Ross Zwisler <zwisler@gmail.com>
Fixes: commit b425e50492 ("block: Avoid that blk_exit_rl() triggers a use-after-free")
Signed-off-by: Bart Van Assche <bart.vanassche@sandisk.com>
Tested-by: Ross Zwisler <ross.zwisler@linux.intel.com>

Updated changelog
Signed-off-by: Jens Axboe <axboe@fb.com>
2017-06-14 13:27:50 -06:00
Dan Carpenter 047385b3dd dm: missing break in process_queued_bios()
his used to be a fall through case, but we shifted code around and I
think we want a break here now.

Fixes: 4e4cbee93d ("block: switch bios to blk_status_t")

Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Acked-by: Mike Snitzer <snitzer@redhat.com>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
2017-06-14 08:22:55 -06:00
Jan Beulich 089bc0143f xen-blkback: don't leak stack data via response ring
Rather than constructing a local structure instance on the stack, fill
the fields directly on the shared ring, just like other backends do.
Build on the fact that all response structure flavors are actually
identical (the old code did make this assumption too).

This is XSA-216.

Cc: stable@vger.kernel.org

Signed-off-by: Jan Beulich <jbeulich@suse.com>
Reviewed-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
Signed-off-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
2017-06-13 16:28:32 -04:00
Juergen Gross a24fa22ce2 xen/blkback: don't use xen_blkif_get() in xen-blkback kthread
There is no need to use xen_blkif_get()/xen_blkif_put() in the kthread
of xen-blkback. Thread stopping is synchronous and using the blkif
reference counting in the kthread will avoid to ever let the reference
count drop to zero at the end of an I/O running concurrent to
disconnecting and multiple rings.

Setting ring->xenblkd to NULL after stopping the kthread isn't needed
as the kthread does this already.

Signed-off-by: Juergen Gross <jgross@suse.com>
Tested-by: Steven Haigh <netwiz@crc.id.au>
Acked-by: Roger Pau Monné <roger.pau@citrix.com>
Signed-off-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
2017-06-13 16:27:39 -04:00
Juergen Gross 71df1d7cca xen/blkback: don't free be structure too early
The be structure must not be freed when freeing the blkif structure
isn't done. Otherwise a use-after-free of be when unmapping the ring
used for communicating with the frontend will occur in case of a
late call of xenblk_disconnect() (e.g. due to an I/O still active
when trying to disconnect).

Signed-off-by: Juergen Gross <jgross@suse.com>
Tested-by: Steven Haigh <netwiz@crc.id.au>
Acked-by: Roger Pau Monné <roger.pau@citrix.com>
Signed-off-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
2017-06-13 16:09:41 -04:00
Juergen Gross 4646441130 xen/blkback: fix disconnect while I/Os in flight
Today disconnecting xen-blkback is broken in case there are still
I/Os in flight: xen_blkif_disconnect() will bail out early without
releasing all resources in the hope it will be called again when
the last request has terminated. This, however, won't happen as
xen_blkif_free() won't be called on termination of the last running
request: xen_blkif_put() won't decrement the blkif refcnt to 0 as
xen_blkif_disconnect() didn't finish before thus some xen_blkif_put()
calls in xen_blkif_disconnect() didn't happen.

To solve this deadlock xen_blkif_disconnect() and
xen_blkif_alloc_rings() shouldn't use xen_blkif_put() and
xen_blkif_get() but use some other way to do their accounting of
resources.

This at once fixes another error in xen_blkif_disconnect(): when it
returned early with -EBUSY for another ring than 0 it would call
xen_blkif_put() again for already handled rings on a subsequent call.
This will lead to inconsistencies in the refcnt handling.

Cc: stable@vger.kernel.org
Signed-off-by: Juergen Gross <jgross@suse.com>
Tested-by: Steven Haigh <netwiz@crc.id.au>
Acked-by: Roger Pau Monné <roger.pau@citrix.com>
Signed-off-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
2017-06-13 16:04:18 -04:00
Christoph Hellwig fe6d53c9c0 nvme: save hmpre and hmmin in struct nvme_ctrl
We'll need the later for the HMB support.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <keith.busch@intel.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
2017-06-13 11:45:35 +02:00
Arnav Dawn b85cf7348a nvme.h: add dword 12 - 15 fields to struct nvme_features
Signed-off-by: Arnav Dawn <a.dawn@samsung.com>
[hch: split from a larger patch, new changelog]
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <keith.busch@intel.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
2017-06-13 11:45:34 +02:00
Christoph Hellwig 39673e1995 nvme.h: add struct nvme_host_mem_buf_desc and HMB flags
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <keith.busch@intel.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
2017-06-13 11:45:33 +02:00
Christoph Hellwig fdd050b5b3 Merge branch 'uuid-types' of bombadil.infradead.org:public_git/uuid into nvme-base 2017-06-13 11:45:14 +02:00
Linus Torvalds 63f700aab4 Xtensa fixes for v4.12-rc6
- don't use linux IRQ #0 in legacy irq domains: fixes timer interrupt
   assignment when it's hardware IRQ # is 0 and the kernel is built w/o
   device tree support;
 - reduce reservation size for double exception vector literals from 48
   to 20 bytes: fixes build on cores with small user exception vector;
 - cleanups: use kmalloc_array instead of kmalloc in simdisk_init and
   seq_puts instead of seq_printf in c_show.
 -----BEGIN PGP SIGNATURE-----
 Version: GnuPG v1
 
 iQIcBAABAgAGBQJZPwZjAAoJEFH5zJH4P6BEFxIP/25rNFHjeJFcUevm6JNR9kz2
 BThpznk0a8I0Nm1PBk6345YfYyC8DOsbR7rClwjjmZePc1ZUfFJU0TFdHlot1scQ
 MASib9qeWToG/kl/JlcC88CJn2uFgbzLXNlVzYpdOAqvYY6sfthf9b0tgdWnByUb
 WLbdg+MN5B+qfhZzNpsKZHHHPv26QV6iwre3ojUk2KgTgGoLHOYo5bcvmr09id0Y
 nWplIteG6RggUxIEghzvB/Uk2pDyYuAjku/dJtFcCShER172v9d6XE8FqV3naTjy
 Boo310fZhLgo93jEUTAjLZHT45vYxstggVRGzRnSiXE+QIqigIxQ76rbqbk8jwWG
 AhQvlNY+XxALYGyQ9SEGcX5JQC9XmjSuuVO8L3I7JeK3MNoH8FkdCrGRoJs2pwJr
 CXBkbvHkSYgaWfStAInFS0Jga8FJ4lCAxKsnVgchB/WoYmqcI9tqGsXnjPa+zOqR
 b9RY6lKeqfVxda1NRQo6TGu03lCFrqHcQZ5fwYPy8oxZfVL3DjQha1E4JZ68GiFI
 E7sEX0W6IIJozHCWruh4acZN/q25OzSnliI0UvPQpPUbPAbI834ouiPXuiJRJNv1
 CffCb2aYFFar4JBEg5t3w87fBUrEe6HDvjVXwwDGqH6HM8kiQyqftMvQ38lQ8g8b
 X3W4SYmFxiqmEaEAvlnr
 =5lPB
 -----END PGP SIGNATURE-----

Merge tag 'xtensa-20170612' of git://github.com/jcmvbkbc/linux-xtensa

Pull Xtensa fixes from Max Filippov:

 - don't use linux IRQ #0 in legacy irq domains: fixes timer interrupt
   assignment when it's hardware IRQ # is 0 and the kernel is built w/o
   device tree support

 - reduce reservation size for double exception vector literals from 48
   to 20 bytes: fixes build on cores with small user exception vector

 - cleanups: use kmalloc_array instead of kmalloc in simdisk_init and
   seq_puts instead of seq_printf in c_show.

* tag 'xtensa-20170612' of git://github.com/jcmvbkbc/linux-xtensa:
  xtensa: don't use linux IRQ #0
  xtensa: reduce double exception literal reservation
  xtensa: ISS: Use kmalloc_array() in simdisk_init()
  xtensa: Use seq_puts() in c_show()
2017-06-13 15:09:10 +09:00
Linus Torvalds 2ab99b001d Merge branch 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/s390/linux
Pull s390 fixes from Martin Schwidefsky:

 - A fix for KVM to avoid kernel oopses in case of host protection
   faults due to runtime instrumentation

 - A fix for the AP bus to avoid dead devices after unbind / bind

 - A fix for a compile warning merged from the vfio_ccw tree

 - Updated default configurations

* 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/s390/linux:
  s390: update defconfig
  s390/zcrypt: Fix blocking queue device after unbind/bind.
  s390/vfio_ccw: make some symbols static
  s390/kvm: do not rely on the ILC on kvm host protection fauls
2017-06-13 15:07:11 +09:00
Jens Axboe f06345add9 blk-mq: fixup type of 'ret' in __blk_mq_try_issue_directly()
Should be a blk_status_t type, not an integer.

Signed-off-by: Jens Axboe <axboe@kernel.dk>