Frame header room is already incluced, just pass the length of payload.
Signed-off-by: Yi Zou <yi.zou@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The FC-LS spec. says ELS timeouts should be 2 x R_A_TOV.
The FC-GS spec. says CT timeouts should be 3 x R_A_TOV.
We've been using E_D_TOV for both of those.
Change for all ELS and CT requests except FLOGI, which we
leave at 2 seconds (using E_D_TOV). One could argue that
R_A_TOV is locally determined until after FLOGI succeeds.
This does change FLOGI for vports which becomes FDISC.
This does not change the REC/SRR timeout which is 2 seconds.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Customers and certification tests have pointed out that we don't
show up on the switch management software as an initiator.
On some MDS switches 'show fcns database' command shows libfc
initiators as 'fcp' not 'fcp:init' like other initiators.
On others switches, I think the switch gets the features by doing a PRLI,
but it may be only certain models or under certain configurations.
Fix this by registering our FC4 features with the RFF_ID CT request
after local port login and after the RFT_ID.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The libfc link up/down messages don't indicate which port is changing.
The Port ID will often be 0.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This is to notify the LLD when an FC_ID is assigned to the local port.
The fnic driver needs to push the assigned FC_ID to firmware.
It currently does this by intercepting the FLOGI responses, and
in order to make that code more common with FIP and NPIV, it
makes more sense to wait until the local port has completely
handled the FLOGI or FDISC response. Also, when we fix
point-to-point FC_ID assignment, we'll need this callback as well.
Add a call to the libfc template, which is called whenever
the local port FC_ID is being assigned. It defaults to
fc_lport_set_fid(), supplied by libfc.
As additional benefit of this function, the LLD may determine
the MAC address that caused the change by looking at the received frame.
We also print the assigned port ID as long as it isn't 0.
Setting port ID to 0 happens often in reset while retrying FLOGI,
and would be uninteresting. This replaces the previous message
which didn't identify the host adapter instance.
patch v2 note: changed one word in a comment. "intercepted" -> "provided".
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch makes a variety of cleanup changes to all libfc files.
This patch adds kernel-doc headers to all functions lacking them
and attempts to better format existing headers. It also add kernel-doc
headers to structures.
This patch ensures that the current naming conventions for local ports,
remote ports and remote port private data is upheld in the following
manner.
struct instance (i.e. variable name)
--------------------------------------------------
fc_lport lport
fc_rport rport
fc_rport_libfc_priv rpriv
fc_rport_priv rdata
I also renamed dns_rp and ptp_rp to dns_rdata and ptp_rdata
respectively.
I used emacs 'indent-region' and 'tabify' on all libfc files
to correct spacing alignments.
I feel sorry for anyone attempting to review this patch.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This is the Open-FCoE implementation of the FC
passthrough support via bsg interface.
Passthrough support is added to both N_Ports and
VN_Ports.
Signed-off-by: Steve Ma <steve.ma@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
They all do the same thing, so combine them into a single function.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Register the fc_host symbolic name as the symbolic port name
with the fabric name server.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Register the fc_host symbolic name as the symbolic node name
with the fabric name server.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
One could interpret FC-GS-5 to say that an explicit RNN_ID is required
before RSNN_NN is allowed to succeed, which is why RNN_ID was not obsoleted
along with RPN_ID acording to this document:
ftp://ftp.t11.org/t11/member/fc/gs-5/05-546v2.pdf
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
RPN_ID has been obsolete per FC-GS-5 for several years. The port name is
registered implicitly as part of FLOGI, and it is undesirable for ports to
change a registered port name using RPN_ID while logged into the fabric.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The FIP code in libfcoe needed several changes to support NPIV
1) dst_src_addr needs to be managed per-n_port-ID for FPMA fabrics with NPIV
enabled. Managing the MAC address is now handled in fcoe, with some slight
changes to update_mac() and a new get_src_addr() function pointer.
2) The libfc elsct_send() hook is used to setup FCoE specific response
handlers for FIP encapsulated ELS exchanges. This lets the FCoE specific
handling know which VN_Port the exchange is for, and doesn't require
tracking OX_IDs. It might be possible to roll back to the full FIP frame
in these, but for now I've just stashed the contents of the MAC address
descriptor in the skb context block for later use. Also, because
fcoe_elsct_send() just passes control on to fc_elsct_send(), all transmits
still come through the normal frame_send() path.
3) The NPIV changes added a mutex hold in the keep alive sending, the lport
mutex is protecting the vport list. We can't take a mutex from a timer,
so move the FIP keep alive logic to the link work struct.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Add FDISC ELS handling to libfc and libfcoe, treat it the same as FLOGI where
appropriate.
Add checking for NPIV support in the FLOGI LS_ACC service parameters.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
NPIV vports are managed in libfc by changing their virtual link state
when the parent N_Ports internal state changes. The vport link is only
online when the N_Port is in a ready state (logged into the fabric).
vport_state is updated as needed in this patch as well, currently the states
LINKDOWN, INITIALIZING, ACTIVE, DSIABLED, and NO_FABRIC_SUPP are used.
This also changes the fc_host port_state handling to differentiate between
LINKDOWN and OFFLINE.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
I'd like to keep basic initialization together with allocation, which means
this can't just be a tail-call to scsi_host_alloc.
This is needed to create a generic libfc host allocation routine for NPIV
VN_Ports, which will share the exchange ID space (through sharing exchange
manager structures) with the parent lport. In order to clone the exchange
manager list when the lport is allocated, the list head must be initialized
earlier.
Also, update fnic to use the libfc_host_alloc so that later changes do not break
it. (contribution by Joe Eykholt)
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
include/scsi/libfc.h is currently loaded with common code
shared between libfc's sub-modules as well as shared between
libfc and fcoe. Previous patches attempted to move out
non-common code. This patch creates two files for common
libfc routines that will not be shared with fcoe, fnic or
any other LLDs.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
I was running into several different panics under stress, which I traced down
to a few different possible slab corruption issues in error handling paths.
I have not yet looked into why these exchange sends fail, but with these
fixes my test system is much more stable under stress than before.
fc_elsct_send() could fail and either leave the passed in frame intact
(failure in fc_ct/els_fill) or the frame could have been freed if the
failure was is fc_exch_seq_send(). The caller had no way of knowing, and
there was a potential double free in the error handling in fc_fcp_rec().
Make fc_elsct_send() always free the frame before returning, and remove the
fc_frame_free() call in fc_fcp_rec().
While fc_exch_seq_send() did always consume the frame, there were double free
bugs in the error handling of fc_fcp_cmd_send() and fc_fcp_srr() as well.
Numerous calls to error handling routines (fc_disc_error(),
fc_lport_error(), fc_rport_error_retry() ) were passing in a frame pointer that
had already been freed in the case of an error. I have changed the call
sites to pass in a NULL pointer, but there may be more appropriate error
codes to use.
Question: Why do these error routines take a frame pointer anyway? I
understand passing in a pointer encoded error to the response handlers, but
the error routines take no action on a valid pointer and should never be
called that way.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
It's possible and harmless to get FLOGI timeouts
while in RESET state. Don't do a WARN_ON in that case.
Also, split out the other WARN_ONs in fc_lport_timeout, so
we can tell which one is hit by its line number.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Fix minor errors.
A debug message said an RLIR was received instead of ECHO.
"Expected" was misspelled in several places.
Fix a type cast from u32 to __be32.
Rob, Some of these may have been also taken care of in your
other doc cleanup patch. Feel free to fold them in.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The local port facility has been replying to ADISC requests without
looking to see if the remote port is logged in. This is incorrect.
An ADISC request requires PLOGI first. It should be rejected if
the sending remote port is not logged in.
This is like other incoming requests that require login, all of
which should be handled in the remote port module.
Move the ADISC request handling from fc_lport.c to fc_rport.c.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Improve lport and rport debug messages to indicate whether
the response is LS_ACC, LS_RJT, closed, or timeout.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This moves the remote port lookup for incoming ELS requests into
fc_rport.c, in preparation for handing PLOGI and LOGO from
unknown rports.
This changes the arg to rport_recv_req from an rdata to an lport.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Currently these values are initialized by the callers. This was exposed
by a later patch that adds PLOGI request support. The patch failed to
initialize the new remote port's roles and it caused problems. This patch
has the rport_create routine initialize the identifiers and then the
callers can override them with real values.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The discovery code had a special-case for the point-to-point mode,
which used a bunch of code that wasn't really needed.
Now that rport_create adds the rport to the discovery list,
completely skip discovery for the point-to-point case.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The list of remote ports (struct fc_rport_priv) has been
maintained by the discovery module. In preparation for having
lport->tt.rport_create() do a lookup first, maintain the
rports list in the rport module. It will still be protected
by the disc_mutex.
The DNS rport is an exception for until after further patches.
For now, do not add it to the list.
The point-to-point rport will be in the discovery list.
So at shutdown, it doesn't need to be separately logged out.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The lport rport callback can only be called for the dNS rport,
since its the only rport who's ops point to that function.
Remove unnecessary checking and debug messages.
Put the locking outside the switch statement as a simplification.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Remote ports will become READY more than once after
ADISC is implemented in a later patch.
The event callback that has been called "CREATED" will mean "READY".
Rename it now in preparation for those changes.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Allow a struct fc_rport_priv to have no fc_rport associated with it.
This sets up to remove the need for "rogue" rports.
Add a few fields to fc_rport_priv that are needed before the fc_rport
is created. These are the ids, maxframe_size, classes, and rport pointer.
Remove the macro PRIV_TO_RPORT(). Just use rdata->rport where appropriate.
To take the place of the get_device()/put_device ops that were used to
hold both the rport and rdata, add a reference count to rdata structures
using kref. When kref_get decrements the refcount to zero, a new template
function releasing the rdata should be called. This will take care of
freeing the rdata and releasing the hold on the rport (for now). After
subsequent patches make the rport truly optional, this release function
will simply free the rdata.
Remove the simple inline function fc_rport_set_name(), which becomes
semanticly ambiguous otherwise. The caller will set the port_name and
node_name in the rdata->Ids, which will later be copied to the rport
when it its created.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
tt.elsct_send is used by both FCP and by the rport state machine.
After further patches, these two modules will use different
structures for the remote port.
So, change elsct_send to use the FC_ID instead of the fc_rport_priv
as its argument. It currently only uses the FC_ID anyway.
For CT requests the destination FC_ID is still implicitly 0xfffffc.
After further patches the did arg on CT requests will be used to
specify the FC_ID being inquired about for GPN_ID or other queries.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The rport and discovery modules deal with remote ports
before fc_remote_port_add() can be done, because the
full set of rport identifiers is not known at early stages.
In preparation for splitting the fc_rport/fc_rport_priv allocation,
make fc_rport_priv the primary interface for the remote port and
discovery engines.
The FCP / SCSI layers still deal with fc_rport and
fc_rport_libfc_priv, however.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The interface for lport->tt.rport_create() takes a fc_disc_port arg,
which is unnatural for most calls. The only reason for this was
to avoid passing in the local port as an argument, but otherwise
added to complexity.
Simplify by just using lport and fc_rport_identifiers.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
While the I/O and LLD interfaces use fc_rport_libfc_priv, the
disc and rport interfaces will use fc_rport_priv, which will
be separately allocated.
Change the disc and rport usage of fc_rport_libfc_priv to fc_rport_priv.
Use #define temporarily to make both names equivalent until a
subsequent patch splits them.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Adds EM list using a anchor struct fc_exch_mgr_anchor, anchor is used
to allow same EM instance sharing across more than one lport on a eth
device, this implementation is per discussed design posted at
http://www.open-fcoe.org/pipermail/devel/2009-June/002566.html.
The shared EM is required for multiple lports on eth device when
using multiple VLANs or NPIV.
Adds fc_exch_mgr_add API to add a EM to the lport and fc_exch_mgr_del
API to delete previously added EM.
Also adds function fc_exch_mgr_destroy() to destroy allocated EM.
The kref is added to the EM to keep track of EM usage count, the EM is
destroyed when no longer in use upon kref reaching to zero.
The caller can specify match function to fc_exch_mgr_add, this
will be used in determining exchange allocation from its EM or not.
Moved calling of fcoe_em_config below fcoe_libfc_config calling,
so that list head lp->ema_list is initialized before configuring
EM.
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
During an fcoe module unload, we saw a problem where fc_rport_work()
finds the lport has been freed. The rdata points to an area
containing 0x6b6b6b6b... the pool poison value from kmem_free().
In fcoe_if_destroy() we call fc_fabric_logoff() then fc_lport_destroy().
fc_fabric_logoff() flushes the remote port work, but we're still receiving
requests, and an RSCN or PLOGI arrives which creates more rports.
Note that although the LLD also checks link_up, it doesn't do it
under the lport mutex, so it can deliver frames to
fc_lport_recv_req() even after link_up is cleared.
So, re-check link_up there.
We need to flush the rports by calling disc_stop_final()
after we clear link_up.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When removing the fcoe module, several lports were being shut down
through fc_lport_fabric_logoff().
Occasionally, one would enter reset state before fc_lport_destroy()
was called, and since link_up was still true, it would log back in.
If we just clear link_up earlier, then we wouldn't be accepting LOGO
requests from other initiators while we are shutting down.
Fix by changing the LOGO response handler to enter DISABLED instead
of RESET. Add an fc_lport_enter_disabled() function which does
what fc_lport_enter_reset() did, except it doesn't proceed to FLOGI state.
Move the code that was common between fc_lport_enter_reset() and
fc_lport_enter_disabled() into a new fc_lport_reset_locked() function.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The state NONE was meant to be invalid, but has been used as
the initial state. Rename it to be DISABLED, as more descriptive.
Further patches will make it the like the RESET state, except
it won't transition to FLOGI until fc_lport_fabric_login() is called.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch adds the /sys/module/libfc/parameters/debug_logging
file to sysfs as a module parameter. It accepts an integer
bitmask for logging. Currently it supports:
bit
LSB 0 = general libfc debugging
1 = lport debugging
2 = disc debugging
3 = rport debugging
4 = fcp debugging
5 = EM debugging
6 = exch/seq debugging
7 = scsi logging (mostly error handling)
the other bits are not used at this time.
The patch converts all of the libfc source files to use
these new macros and removes the old FC_DBG macro.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
After lport_destroy, the local port should not be used again. Transition
to state NONE, any incoming frames or link up should not transition out
of this state since we are deleting exchange table and cleaning up the
local port. Also, mark link as down.
Signed-off-by: Abhijeet Joglekar <abjoglek@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
We want to generate the rport queue event (from the logoff)
before flushing the queue otherwise the event may still be
in the queue when we logoff.
Signed-off-by: Abhijeet Joglekar <abjoglek@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
For instance, if there is a Plogi pending (remote port is in Plogi state),
and the state changes to say NONE (because the port is being logged off),
then when the Plogi resp times out, do not start a retry.
This patch partially reverts an earlier patch (libfc: check for err when
recv and state is incorrect), by moving the state check back to before
checking for error. However, if the state does not match, then there is
an additional check to see if its an error ptr or a real frame before
jumping to err or out respectively.
Signed-off-by: Abhijeet Joglekar <abjoglek@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Remove the hotplug creation of dev_stats, we allocate for all possible CPUs
now when we allocate the lport.
v2: Durring the 2.6.30 merge window, before these patches were comitted,
'percpu_ptr' was renamed 'per_cpu_ptr'. This latest update updates this
patch for the name change.
Signed-off-by: Yi Zou <yi.zou@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
I got the following warnings on IA64:
drivers/scsi/libfc/fc_lport.c: In function 'fc_lport_recv_flogi_req':
drivers/scsi/libfc/fc_lport.c:788: warning: format '%llx' expects type 'long long unsigned int', but argument 3 has type 'u64'
drivers/scsi/libfc/fc_lport.c:792: warning: format '%llx' expects type 'long long unsigned int', but argument 3 has type 'u64'
scsi/libfc/fc_rport.c: In function 'fc_rport_recv_plogi_req':
/home/fujita/git/linux-2.6/drivers/scsi/libfc/fc_rport.c:968: warning: format '%llx' expects type 'long long unsigned int', but argument 4 has type 'u64'
Signed-off-by: FUJITA Tomonori <fujita.tomonori@lab.ntt.co.jp>
Cc: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
1) Added '()' for function names in kerneldoc comments
2) Changed comment bookends from '**/' to '*/'. The comment on the the
mailing list was that '**/' "is consistently unconventional. Not
wrong, just odd." The Documentation/kernel-doc-nano-HOWTO.txt
states that kerneldoc comment blocks should end with '**/' but most
(if not all) instance I found under drivers/scsi/ were only using
the '*/' so I converted to that style.
3) Removed incorrect linebreaks in kerneldoc comments where found
4) Removed a few unnecessary blank comment lines in kerneldoc comment
blocks
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
If we've just created an interface and the an rport is
logging in we may have a request on the wire (say PRLI).
If we destroy the interface, we'll go through each rport
on the disc->rports list and set each rport's state to NONE.
Then the lport will reset the EM. The EM reset will send a
CLOSED event to the prli_resp() handler which will notice
that the state != PRLI. In this case it frees the frame
pointer, decrements the refcount and unlocks the rport.
The problem is that there isn't a frame in this case. It's
just a pointer with an embedded error code. The free causes
an Oops.
This patch moves the error checking to be before the state
checking.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
When a sequence cannot be delivered to the target, the local
port will schedule retries, While this process is in progress,
if we destroy the FCoE interface, the fcoe_sw_destroy routine is
entered, and the fc_exch_mgr_free(lp->emp) is called. Thus
if fc_exch_alloc() is called when retrying the sequence,
the mempool_alloc() will fail to allocate the exchange because
the mempool of the exchange manager has already been released.
This patch is to cancel any pending retry work of the local
port before we start to destroy the interface.
Also, when resetting the local port, we should also stop the
scheduled pending retries.
Signed-off-by: Steve Ma <steve.ma@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>