b04b908d8a
This allows AC charging to be turned off, much like usb charging. "continuous" mode is not available though. Acked-by: Pavel Machek <pavel@ucw.cz> Signed-off-by: NeilBrown <neil@brown.name> Signed-off-by: Sebastian Reichel <sre@kernel.org>
46 lines
1.3 KiB
Plaintext
46 lines
1.3 KiB
Plaintext
What: /sys/class/power_supply/twl4030_ac/max_current
|
|
/sys/class/power_supply/twl4030_usb/max_current
|
|
Description:
|
|
Read/Write limit on current which may
|
|
be drawn from the ac (Accessory Charger) or
|
|
USB port.
|
|
|
|
Value is in micro-Amps.
|
|
|
|
Value is set automatically to an appropriate
|
|
value when a cable is plugged or unplugged.
|
|
|
|
Value can the set by writing to the attribute.
|
|
The change will only persist until the next
|
|
plug event. These event are reported via udev.
|
|
|
|
|
|
What: /sys/class/power_supply/twl4030_usb/mode
|
|
Description:
|
|
Changing mode for USB port.
|
|
Writing to this can disable charging.
|
|
|
|
Possible values are:
|
|
"auto" - draw power as appropriate for detected
|
|
power source and battery status.
|
|
"off" - do not draw any power.
|
|
"continuous"
|
|
- activate mode described as "linear" in
|
|
TWL data sheets. This uses whatever
|
|
current is available and doesn't switch off
|
|
when voltage drops.
|
|
|
|
This is useful for unstable power sources
|
|
such as bicycle dynamo, but care should
|
|
be taken that battery is not over-charged.
|
|
|
|
What: /sys/class/power_supply/twl4030_ac/mode
|
|
Description:
|
|
Changing mode for 'ac' port.
|
|
Writing to this can disable charging.
|
|
|
|
Possible values are:
|
|
"auto" - draw power as appropriate for detected
|
|
power source and battery status.
|
|
"off" - do not draw any power.
|