9705ecc5c1
The battery charger state machine switches into charging mode when the battery voltage falls below 96% of a battery float voltage. But the voltage drop in Li-ion batteries is marginal(1~2 %) till about 80% of its capacity - which means, after a BATFULL, charging won't be restarted until 80%. This work_struct function restarts charging at regular intervals to make sure the battery doesn't discharge too much. Signed-off-by: Balaji Rao <balajirrao@openmoko.org> Cc: Andy Green <andy@openmoko.com> Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com> |
||
---|---|---|
.. | ||
apm_power.c | ||
bq27x00_battery.c | ||
da9030_battery.c | ||
ds2760_battery.c | ||
Kconfig | ||
Makefile | ||
olpc_battery.c | ||
pcf50633-charger.c | ||
pda_power.c | ||
pmu_battery.c | ||
power_supply_core.c | ||
power_supply_leds.c | ||
power_supply_sysfs.c | ||
power_supply.h | ||
tosa_battery.c | ||
wm97xx_battery.c | ||
wm8350_power.c |