David Brownell c22fa3acbc [PATCH] spin longer for ehci port reset completion
This makes the EHCI driver spin a bit longer before concluding that the
port reset failed.  "Obviously safe."

It allows some devices to enumerate that previously didn't.  We've seen
a bunch of these problem reports recently, this will make some go away.

As reported by Michael Zapf <Michael.Zapf@uni-kassel.de>, some EHCI
controllers seem to take forever to finish port resets and produce
"port N reset error -110" type errors.  Spinning a bit longer helps.

Signed-off-by: David Brownell <dbrownell@users.sourceforge.net>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2005-06-13 08:20:41 -07:00
..
2005-05-31 14:13:58 -07:00
2005-05-31 14:13:58 -07:00
2005-05-31 14:13:58 -07:00
2005-05-31 14:13:58 -07:00