Thomas Gleixner 07454bfff1 clockevents: check broadcast tick device not the clock events device
Impact: jiffies increment too fast.

Hugh Dickins noted that with NOHZ=n and HIGHRES=n jiffies get
incremented too fast. The reason is a wrong check in the broadcast
enter/exit code, which keeps the local apic timer in periodic mode
when the switch happens.

Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
2008-10-04 10:51:07 +02:00
..
2008-05-01 08:03:59 -07:00
2008-07-26 20:53:20 -04:00
2008-07-28 16:30:21 -07:00
2008-07-28 14:37:38 +02:00
2008-07-26 12:00:09 -07:00
2008-08-13 12:55:10 +02:00
2008-09-02 19:21:40 -07:00
2008-08-25 17:39:57 +02:00
2008-08-11 14:49:29 +02:00
2008-08-19 20:37:07 -07:00
2008-07-25 10:53:45 -07:00
2008-04-30 08:29:53 -07:00