hw/scsi/scsi-generic: Fix io_timeout property not applying
The io_timeout property, introduced inc9b6609
(part of 6.0) is silently overwritten by the hardcoded default value of 30 seconds (DEFAULT_IO_TIMEOUT) in scsi_generic_realize because that function is being called after the properties have already been applied. The property definition already has a default value which is applied correctly when no value is explicitly set, so we can just remove the code which overrides the io_timeout completely. This has been tested by stracing SG_IO operations with the io_timeout property set and unset and now sets the timeout field in the ioctl request to the proper value. Fixes:c9b6609b69
("scsi: make io_timeout configurable") Signed-off-by: Lorenz Brun <lorenz@brun.one> Message-ID: <20240315145831.2531695-1-lorenz@brun.one> Reviewed-by: Alex Bennée <alex.bennee@linaro.org> Signed-off-by: Philippe Mathieu-Daudé <philmd@linaro.org>
This commit is contained in:
parent
9dab7bbb01
commit
7c7a9f578e
@ -752,7 +752,6 @@ static void scsi_generic_realize(SCSIDevice *s, Error **errp)
|
|||||||
|
|
||||||
/* Only used by scsi-block, but initialize it nevertheless to be clean. */
|
/* Only used by scsi-block, but initialize it nevertheless to be clean. */
|
||||||
s->default_scsi_version = -1;
|
s->default_scsi_version = -1;
|
||||||
s->io_timeout = DEFAULT_IO_TIMEOUT;
|
|
||||||
scsi_generic_read_device_inquiry(s);
|
scsi_generic_read_device_inquiry(s);
|
||||||
}
|
}
|
||||||
|
|
||||||
|
Loading…
Reference in New Issue