cadance_uart: Accept input after rx FIFO pop
The device returns false from the can receive function when the FIFO is full. This means the device should check for buffered input whenever a byte is popped from the FIFO. Reported-by: Jason Wu <huanyu@xilinx.com> Signed-off-by: Peter Crosthwaite <peter.crosthwaite@xilinx.com> Message-id: 1360632571-25638-1-git-send-email-peter.crosthwaite@xilinx.com Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
This commit is contained in:
parent
8a8f584008
commit
9893c80d81
@ -343,6 +343,7 @@ static void uart_read_rx_fifo(UartState *s, uint32_t *c)
|
||||
if (!s->rx_count) {
|
||||
s->r[R_SR] |= UART_SR_INTR_REMPTY;
|
||||
}
|
||||
qemu_chr_accept_input(s->chr);
|
||||
} else {
|
||||
*c = 0;
|
||||
s->r[R_SR] |= UART_SR_INTR_REMPTY;
|
||||
|