e1000: Avoid infinite loop in processing transmit descriptor (CVE-2015-6815)
While processing transmit descriptors, it could lead to an infinite loop if 'bytes' was to become zero; Add a check to avoid it. [The guest can force 'bytes' to 0 by setting the hdr_len and mss descriptor fields to 0. --Stefan] Signed-off-by: P J P <pjp@fedoraproject.org> Signed-off-by: Stefan Hajnoczi <stefanha@redhat.com> Reviewed-by: Thomas Huth <thuth@redhat.com> Message-id: 1441383666-6590-1-git-send-email-stefanha@redhat.com
This commit is contained in:
parent
2752e5bedb
commit
b947ac2bf2
@ -740,7 +740,8 @@ process_tx_desc(E1000State *s, struct e1000_tx_desc *dp)
|
||||
memmove(tp->data, tp->header, tp->hdr_len);
|
||||
tp->size = tp->hdr_len;
|
||||
}
|
||||
} while (split_size -= bytes);
|
||||
split_size -= bytes;
|
||||
} while (bytes && split_size);
|
||||
} else if (!tp->tse && tp->cptse) {
|
||||
// context descriptor TSE is not set, while data descriptor TSE is set
|
||||
DBGOUT(TXERR, "TCP segmentation error\n");
|
||||
|