Commit Graph

10 Commits

Author SHA1 Message Date
Markus Armbruster 64eaa82095 hw: Replace trivial drive_get_next() by drive_get()
drive_get_next() is basically a bad idea.  It returns the "next" block
backend of a certain interface type.  "Next" means bus=0,unit=N, where
subsequent calls count N up from zero, per interface type.

This lets you define unit numbers implicitly by execution order.  If the
order changes, or new calls appear "in the middle", unit numbers change.
ABI break.  Hard to spot in review.

A number of machines connect just one backend with drive_get_next().
Change them to use drive_get() directly.  This makes the (zero) unit
number explicit in the code.

Cc: Beniamino Galvani <b.galvani@gmail.com>
Cc: Peter Maydell <peter.maydell@linaro.org>
Cc: Subbaraya Sundeep <sundeep.lkml@gmail.com>
Cc: Niek Linnenbank <nieklinnenbank@gmail.com>
Cc: Andrew Baumann <Andrew.Baumann@microsoft.com>
Cc: "Philippe Mathieu-Daudé" <f4bug@amsat.org>
Cc: Jean-Christophe Dubois <jcd@tribudubois.net>
Cc: Alistair Francis <Alistair.Francis@wdc.com>
Cc: Bin Meng <bin.meng@windriver.com>
Cc: Palmer Dabbelt <palmer@dabbelt.com>
Cc: Artyom Tarasenko <atar4qemu@gmail.com>
Cc: Mark Cave-Ayland <mark.cave-ayland@ilande.co.uk>
Cc: Michael Tokarev <mjt@tls.msk.ru>
Cc: Laurent Vivier <laurent@vivier.eu>
Cc: qemu-arm@nongnu.org
Cc: qemu-riscv@nongnu.org
Signed-off-by: Markus Armbruster <armbru@redhat.com>
Message-Id: <20211117163409.3587705-3-armbru@redhat.com>
2021-12-15 08:38:16 +01:00
Philippe Mathieu-Daudé 526e744302 hw/misc/sifive_u_otp: Do not reset OTP content on hardware reset
Once a "One Time Programmable" is programmed, it shouldn't be reset.

Do not re-initialize the OTP content in the DeviceReset handler,
initialize it once in the DeviceRealize one.

Fixes: 9fb45c62ae ("riscv: sifive: Implement a model for SiFive FU540 OTP")
Signed-off-by: Philippe Mathieu-Daudé <f4bug@amsat.org>
Reviewed-by: Alistair Francis <alistair.francis@wdc.com>
Message-Id: <20211119104757.331579-1-f4bug@amsat.org>
Signed-off-by: Alistair Francis <alistair.francis@wdc.com>
2021-11-22 10:46:22 +10:00
Thomas Huth 6b717a8d44 hw/misc/sifive_u_otp: Use IF_PFLASH for the OTP device instead of IF_NONE
Configuring a drive with "if=none" is meant for creation of a backend
only, it should not get automatically assigned to a device frontend.
Use "if=pflash" for the One-Time-Programmable device instead (like
it is e.g. also done for the efuse device in hw/arm/xlnx-zcu102.c).

Since the old way of configuring the device has already been published
with the previous QEMU versions, we cannot remove this immediately, but
have to deprecate it and support it for at least two more releases.

Signed-off-by: Thomas Huth <thuth@redhat.com>
Acked-by: Philippe Mathieu-Daudé <philmd@redhat.com>
Reviewed-by: Markus Armbruster <armbru@redhat.com>
Reviewed-by: Alistair Francis <alistair.francis@wdc.com>
Message-id: 20211119102549.217755-1-thuth@redhat.com
Signed-off-by: Alistair Francis <alistair.francis@wdc.com>
2021-11-22 10:43:54 +10:00
Bin Meng a033d8008d hw/misc: sifive_u_otp: Use error_report() when block operation fails
At present when blk_pread() / blk_pwrite() fails, a guest error
is logged, but this is not really a guest error. Change to use
error_report() instead.

Signed-off-by: Bin Meng <bin.meng@windriver.com>
Reviewed-by: Philippe Mathieu-Daudé <f4bug@amsat.org>
Reviewed-by: Alistair Francis <alistair.francis@wdc.com>
Message-id: 1611026585-29971-1-git-send-email-bmeng.cn@gmail.com
Signed-off-by: Alistair Francis <alistair.francis@wdc.com>
2021-03-04 09:43:29 -05:00
Kevin Wolf 86b1cf3227 block: Separate blk_is_writable() and blk_supports_write_perm()
Currently, blk_is_read_only() tells whether a given BlockBackend can
only be used in read-only mode because its root node is read-only. Some
callers actually try to answer a slightly different question: Is the
BlockBackend configured to be writable, by taking write permissions on
the root node?

This can differ, for example, for CD-ROM devices which don't take write
permissions, but may be backed by a writable image file. scsi-cd allows
write requests to the drive if blk_is_read_only() returns false.
However, the write request will immediately run into an assertion
failure because the write permission is missing.

This patch introduces separate functions for both questions.
blk_supports_write_perm() answers the question whether the block
node/image file can support writable devices, whereas blk_is_writable()
tells whether the BlockBackend is currently configured to be writable.

All calls of blk_is_read_only() are converted to one of the two new
functions.

Fixes: https://bugs.launchpad.net/bugs/1906693
Cc: qemu-stable@nongnu.org
Signed-off-by: Kevin Wolf <kwolf@redhat.com>
Message-Id: <20210118123448.307825-2-kwolf@redhat.com>
Reviewed-by: Philippe Mathieu-Daudé <philmd@redhat.com>
Reviewed-by: Max Reitz <mreitz@redhat.com>
Signed-off-by: Kevin Wolf <kwolf@redhat.com>
2021-01-27 20:45:20 +01:00
Green Wan 29b5fe0dcd hw/misc/sifive_u_otp: handling the fails of blk_pread and blk_pwrite
Fix code coverage issues by checking return value and handling fail case
of blk_pread() and blk_pwrite(). Return default value 0xff if read fails.

Fixes: Coverity CID 1435959
Fixes: Coverity CID 1435960
Fixes: Coverity CID 1435961
Signed-off-by: Green Wan <green.wan@sifive.com>
Reviewed-by: Alistair Francis <alistair.francis@wdc.com>
Message-id: 20201104092900.21214-1-green.wan@sifive.com
Signed-off-by: Alistair Francis <alistair.francis@wdc.com>
2021-01-16 10:57:21 -08:00
Eduardo Habkost ce35e2295e qdev: Move softmmu properties to qdev-properties-system.h
Move the property types and property macros implemented in
qdev-properties-system.c to a new qdev-properties-system.h
header.

Signed-off-by: Eduardo Habkost <ehabkost@redhat.com>
Reviewed-by: Igor Mammedov <imammedo@redhat.com>
Message-Id: <20201211220529.2290218-16-ehabkost@redhat.com>
Signed-off-by: Eduardo Habkost <ehabkost@redhat.com>
2020-12-18 15:20:17 -05:00
Green Wan 51b6c1bbc3 hw/misc/sifive_u_otp: Add backend drive support
Add '-drive' support to OTP device. Allow users to assign a raw file
as OTP image.

test commands for 16k otp.img filled with zero:

$ dd if=/dev/zero of=./otp.img bs=1k count=16
$ ./qemu-system-riscv64 -M sifive_u -m 256M -nographic -bios none \
-kernel ../opensbi/build/platform/sifive/fu540/firmware/fw_payload.elf \
-d guest_errors -drive if=none,format=raw,file=otp.img

Signed-off-by: Green Wan <green.wan@sifive.com>
Reviewed-by: Bin Meng <bin.meng@windriver.com>
Tested-by: Bin Meng <bin.meng@windriver.com>
Acked-by: Alistair Francis <alistair.francis@wdc.com>
Message-id: 20201020033732.12921-3-green.wan@sifive.com
Signed-off-by: Alistair Francis <alistair.francis@wdc.com>
2020-10-22 12:00:50 -07:00
Green Wan a54d259157 hw/misc/sifive_u_otp: Add write function and write-once protection
- Add write operation to update fuse data bit when PWE bit is on.
 - Add array, fuse_wo, to store the 'written' status for all bits
   of OTP to block the write operation.

Signed-off-by: Green Wan <green.wan@sifive.com>
Reviewed-by: Alistair Francis <alistair.francis@wdc.com>
Reviewed-by: Bin Meng <bin.meng@windriver.com>
Tested-by: Bin Meng <bin.meng@windriver.com>
Message-id: 20201020033732.12921-2-green.wan@sifive.com
Signed-off-by: Alistair Francis <alistair.francis@wdc.com>
2020-10-22 12:00:46 -07:00
Bin Meng 0fa9e32945 hw/riscv: Move sifive_u_otp model to hw/misc
This is an effort to clean up the hw/riscv directory. Ideally it
should only contain the RISC-V SoC / machine codes plus generic
codes. Let's move sifive_u_otp model to hw/misc directory.

Signed-off-by: Bin Meng <bin.meng@windriver.com>
Reviewed-by: Alistair Francis <alistair.francis@wdc.com>
Message-Id: <1599129623-68957-4-git-send-email-bmeng.cn@gmail.com>
Signed-off-by: Alistair Francis <alistair.francis@wdc.com>
2020-09-09 15:54:19 -07:00