69 lines
2.9 KiB
ReStructuredText
69 lines
2.9 KiB
ReStructuredText
======================================
|
|
QEMU virtio-net standby (net_failover)
|
|
======================================
|
|
|
|
This document explains the setup and usage of virtio-net standby feature which
|
|
is used to create a net_failover pair of devices.
|
|
|
|
The general idea is that we have a pair of devices, a (vfio-)pci and a
|
|
virtio-net device. Before migration the vfio device is unplugged and data flows
|
|
through the virtio-net device, on the target side another vfio-pci device is
|
|
plugged in to take over the data-path. In the guest the net_failover kernel
|
|
module will pair net devices with the same MAC address.
|
|
|
|
The two devices are called primary and standby device. The fast hardware based
|
|
networking device is called the primary device and the virtio-net device is the
|
|
standby device.
|
|
|
|
Restrictions
|
|
------------
|
|
|
|
Currently only PCIe devices are allowed as primary devices, this restriction
|
|
can be lifted in the future with enhanced QEMU support. Also, only networking
|
|
devices are allowed as primary device. The user needs to ensure that primary
|
|
and standby devices are not plugged into the same PCIe slot.
|
|
|
|
Usecase
|
|
-------
|
|
|
|
Virtio-net standby allows easy migration while using a passed-through fast
|
|
networking device by falling back to a virtio-net device for the duration of
|
|
the migration. It is like a simple version of a bond, the difference is that it
|
|
requires no configuration in the guest. When a guest is live-migrated to
|
|
another host QEMU will unplug the primary device via the PCIe based hotplug
|
|
handler and traffic will go through the virtio-net device. On the target
|
|
system the primary device will be automatically plugged back and the
|
|
net_failover module registers it again as the primary device.
|
|
|
|
Usage
|
|
-----
|
|
|
|
The primary device can be hotplugged or be part of the startup configuration
|
|
|
|
-device virtio-net-pci,netdev=hostnet1,id=net1,mac=52:54:00:6f:55:cc, \
|
|
bus=root2,failover=on
|
|
|
|
With the parameter failover=on the VIRTIO_NET_F_STANDBY feature will be enabled.
|
|
|
|
-device vfio-pci,host=5e:00.2,id=hostdev0,bus=root1,failover_pair_id=net1
|
|
|
|
failover_pair_id references the id of the virtio-net standby device. This
|
|
is only for pairing the devices within QEMU. The guest kernel module
|
|
net_failover will match devices with identical MAC addresses.
|
|
|
|
Hotplug
|
|
-------
|
|
|
|
Both primary and standby device can be hotplugged via the QEMU monitor. Note
|
|
that if the virtio-net device is plugged first a warning will be issued that it
|
|
couldn't find the primary device.
|
|
|
|
Migration
|
|
---------
|
|
|
|
A new migration state wait-unplug was added for this feature. If failover primary
|
|
devices are present in the configuration, migration will go into this state.
|
|
It will wait until the device unplug is completed in the guest and then move into
|
|
active state. On the target system the primary devices will be automatically hotplugged
|
|
when the feature bit was negotiated for the virtio-net standby device.
|