Peter Maydell 6069bbc904 hw/misc/iotkit-sysctl: Implement SSE-200 and SSE-300 PID register values
The SSE-200 and SSE-300 have different PID register values from the
IoTKit for the sysctl register block.  We incorrectly implemented the
SSE-200 with the same PID values as IoTKit.  Fix the SSE-200 bug and
report these register values for SSE-300.

Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
Tested-by: Philippe Mathieu-Daudé <f4bug@amsat.org>
Reviewed-by: Richard Henderson <richard.henderson@linaro.org>
Message-id: 20210219144617.4782-19-peter.maydell@linaro.org
2021-03-08 17:20:02 +00:00
..
2021-02-20 12:36:19 +01:00
2020-12-08 13:48:57 -05:00
2021-02-08 15:15:32 +01:00