Jim Shu 1aae4a12da hw/intc: sifive_plic: change interrupt priority register to WARL field
PLIC spec [1] requires interrupt source priority registers are WARL
field and the number of supported priority is power-of-2 to simplify SW
discovery.

Existing QEMU RISC-V machine (e.g. shakti_c) don't strictly follow PLIC
spec, whose number of supported priority is not power-of-2. Just change
each bit of interrupt priority register to WARL field when the number of
supported priority is power-of-2.

[1] https://github.com/riscv/riscv-plic-spec/blob/master/riscv-plic.adoc#interrupt-priorities

Signed-off-by: Jim Shu <jim.shu@sifive.com>
Reviewed-by: Clément Chigot <chigot@adacore.com>
Acked-by: Alistair Francis <alistair.francis@wdc.com>
Message-Id: <20221003041440.2320-3-jim.shu@sifive.com>
Signed-off-by: Alistair Francis <alistair.francis@wdc.com>